All MIBs › SL-XPDR-MIB › xpdrConnAddMask
xpdrConnAddMask
Module: SL-XPDR-MIB
OID (symbolic): SL-XPDR-MIB::xpdrConnAddMask
OID (numeric): 1.3.6.1.4.1.4515.1.8.1.1.1.7
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: This object is a bit mask relevant only for Muxponder entry. It contains a bit for each Muxponder service. To add a service the management should set the corresponding bit to 1. To remove a service the bit should be set to 0.
For ODU allocation, the value of xpdrConnAddMask should be set to reflect the odus/time-slots provisioned for the service according to the following rules: a. For ODU1 the first byte is 0; for ODU0 the first byte is 1. b. The second byte. Is equal to: i. The 4 bits of the first nibble correspond to Uplink 1 allocated odus counted from right to left ii. The 4 bits of the second nibble correspond to Uplink 2 allocated odus counted from right to left c. The Third and Forth bytes keep bit-mask of the allocated time-slots within the odu.
What is xpdrConnAddMask?
xpdrConnAddMask is a bitmask, relevant only to Muxponder entries, where each bit corresponds to a specific Muxponder service or, for ODU allocation, to a specific ODU/time-slot on Uplink 1 or Uplink 2. An admin sets a bit to 1 to add a given service or ODU/time-slot to the connection and clears it to 0 to remove it, following the described byte layout where the first byte distinguishes ODU1 from ODU0 allocation and later bytes encode the uplink and time-slot bits. For example, to add ODU0 service allocated to the first two odus of Uplink 1, an admin would set the first byte to 1 and set the corresponding bits in the second byte's first nibble to reflect those two odus.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4515.1.8.1.1.1.7 snmpwalk -v2c -c public <target> SL-XPDR-MIB::xpdrConnAddMask
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.4515.1.8.1.1.1.7.1 snmpget -v2c -c public <target> SL-XPDR-MIB::xpdrConnAddMask.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.4515.1.8.1.1.1.7.1 i <value>
Start monitoring Smartoptics SiteLight optical transponder/transport platform (ODU cross-connect/rate-control status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SL-XPDR-MIB::xpdrConnAddMask OID value, configure state conditions and alerts, and monitor any Smartoptics SiteLight optical transponder/transport platform (ODU cross-connect/rate-control status) from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.4515 | smartoptics | SL-NE-MIB |
| 1.3.6.1.4.1.4515.1 | sitelight | SL-NE-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.4515.1.8 | slXpdr | SL-XPDR-MIB |
| 1.3.6.1.4.1.4515.1.8.1 | slXpdrConn | SL-XPDR-MIB |
| 1.3.6.1.4.1.4515.1.8.1.1 | xpdrConnConfigTable | SL-XPDR-MIB |
| 1.3.6.1.4.1.4515.1.8.1.1.1 | xpdrConnConfigEntry | SL-XPDR-MIB |