slSonetApsLineSwitchReason

Module: SL-SONET-APS-MIB

OID (symbolic): SL-SONET-APS-MIB::slSonetApsLineSwitchReason

OID (numeric): 1.3.6.1.4.1.4515.1.6.5.1.1.1.18

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The reason why APS switch happened. When the working line on one end fails, its other end is told to do an APS switch. The following options in the increasing order of priority indicate what type of switch request it is.

slSonetApsRevertive : Switch back to working line after the Wait-to-Restore interval is over, and failures are cleared. It is the lowest priority. slSonetApsManual : Manual switch causes APS switch unless a request of equal or higher priority is in effect. slSonetApsSignalDefectLow : Switch happened because threshold for 'slSonetApsSigFaultBER' was exceeded. slSonetApsSignalDefectHigh : Same as above, but higher priority. slSonetApsSignalFailureLow : Switch happened because threshold for 'slSonetApsSigDegradeBER' was exceeded. slSonetApsSignalFailureHigh : Same as above, but higher priority. slSonetApsForceSwitch : Forced switch forces hardware to switch the active line even if the other line (could be working line or protection line) is in alarm. slSonetApsLockOut : This is the highest priority switch. This will override all other requests. slSonetApsRemoteRequest : indicates that the local switchover was in response to a remote request to switch. slSonetApsLockOut : indicates that the last switchover to the working occurred because of protection lockout.

What is slSonetApsLineSwitchReason?

A read-only value reporting why the last APS switch occurred, ranked by increasing priority: other, revertive, manual, signal degrade, signal failure, force switch, remote request, or lockout. An admin checks this after an unexpected switchover to distinguish, for example, an automatic signalFailure-triggered switch from a deliberate manual one.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4515.1.6.5.1.1.1.18
snmpwalk -v2c -c public <target> SL-SONET-APS-MIB::slSonetApsLineSwitchReason

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.4515.1.6.5.1.1.1.18.1
snmpget -v2c -c public <target> SL-SONET-APS-MIB::slSonetApsLineSwitchReason.1

Start monitoring SmartOptics SiteLight SONET optical transport equipment (SONET Automatic Protection Switching status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SL-SONET-APS-MIB::slSonetApsLineSwitchReason OID value, configure state conditions and alerts, and monitor any SmartOptics SiteLight SONET optical transport equipment (SONET Automatic Protection Switching status) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.4515smartopticsSL-NE-MIB
1.3.6.1.4.1.4515.1sitelightSL-NE-MIB
1.3.6.1.4.1.4515.1.6slSonetMibSL-SONET-MIB
Numeric OIDNameModule
1.3.6.1.4.1.4515.1.6.5slSonetApsMibSL-SONET-APS-MIB
1.3.6.1.4.1.4515.1.6.5.1slSonetApsConfigSL-SONET-APS-MIB
1.3.6.1.4.1.4515.1.6.5.1.1slSonetApsConfigTableSL-SONET-APS-MIB
1.3.6.1.4.1.4515.1.6.5.1.1.1slSonetApsConfigEntrySL-SONET-APS-MIB
1.3.6.1.4.1.4515.1.6.5.1.1.1.18slSonetApsLineSwitchReasonSL-SONET-APS-MIB