SL-SONET-APS-MIB :: slSonetApsChanSignalDegrades

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SL-SONET-APS-MIB › slSonetApsChanSignalDegrades

slSonetApsChanSignalDegrades

Module: SL-SONET-APS-MIB

OID (symbolic): SL-SONET-APS-MIB::slSonetApsChanSignalDegrades

OID (numeric): 1.3.6.1.4.1.4515.1.6.5.1.1.1.13

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: A count of Signal Degrade conditions. This condition occurs when the line Bit Error Rate exceeds the currently configured threshold.

What is slSonetApsChanSignalDegrades?

A read-only counter of Signal Degrade conditions detected on this line, which occur when the bit error rate exceeds the configured threshold. A steadily climbing count points to a marginal SONET line worth physically inspecting even if it hasn't triggered a full switchover yet.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4515.1.6.5.1.1.1.13
snmpwalk -v2c -c public <target> SL-SONET-APS-MIB::slSonetApsChanSignalDegrades

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.4515.1.6.5.1.1.1.13.1
snmpget -v2c -c public <target> SL-SONET-APS-MIB::slSonetApsChanSignalDegrades.1

Start monitoring SmartOptics SiteLight SONET optical transport equipment (SONET Automatic Protection Switching status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SL-SONET-APS-MIB::slSonetApsChanSignalDegrades OID value, configure state conditions and alerts, and monitor any SmartOptics SiteLight SONET optical transport equipment (SONET Automatic Protection Switching status) from a single console.

How to Use in IPNetwork Monitor

Select a SmartOptics SiteLight SONET optical transport equipment (SONET Automatic Protection Switching status) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type slSonetApsChanSignalDegrades into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports a count of Signal Degrade conditions. This condition occurs when the line Bit Error Rate exceeds the currently configured threshold. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases between polls, since a rising count of errors, failures, or discards often points to a real underlying problem. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.4515smartopticsSL-NE-MIB
1.3.6.1.4.1.4515.1sitelightSL-NE-MIB
1.3.6.1.4.1.4515.1.6slSonetMibSL-SONET-MIB
Numeric OIDNameModule
1.3.6.1.4.1.4515.1.6.5slSonetApsMibSL-SONET-APS-MIB
1.3.6.1.4.1.4515.1.6.5.1slSonetApsConfigSL-SONET-APS-MIB
1.3.6.1.4.1.4515.1.6.5.1.1slSonetApsConfigTableSL-SONET-APS-MIB
1.3.6.1.4.1.4515.1.6.5.1.1.1slSonetApsConfigEntrySL-SONET-APS-MIB
1.3.6.1.4.1.4515.1.6.5.1.1.1.13slSonetApsChanSignalDegradesSL-SONET-APS-MIB