SL-SONET-ALARM-MIB :: slSonetAlarmSeverity

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SL-SONET-ALARM-MIB › slSonetAlarmSeverity

slSonetAlarmSeverity

Module: SL-SONET-ALARM-MIB

OID (symbolic): SL-SONET-ALARM-MIB::slSonetAlarmSeverity

OID (numeric): 1.3.6.1.4.1.4515.1.6.4.2.1

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The alarm severity.

What is slSonetAlarmSeverity?

This object reports the severity level assigned to a SONET alarm trap. An admin uses this value to triage incoming slSonetAlarmTrap notifications, prioritizing critical alarms for immediate response over minor ones. For example, slSonetAlarmSeverity reporting critical(1) in a trap tells the admin to investigate that SONET interface immediately rather than queue it for routine review.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4515.1.6.4.2.1
snmpwalk -v2c -c public <target> SL-SONET-ALARM-MIB::slSonetAlarmSeverity

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.4515.1.6.4.2.1.1
snmpget -v2c -c public <target> SL-SONET-ALARM-MIB::slSonetAlarmSeverity.1

Start monitoring Smartoptics SiteLight SONET/optical transport equipment (SONET-layer alarm status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SL-SONET-ALARM-MIB::slSonetAlarmSeverity OID value, configure state conditions and alerts, and monitor any Smartoptics SiteLight SONET/optical transport equipment (SONET-layer alarm status) from a single console.

How to Use in IPNetwork Monitor

Select a Smartoptics SiteLight SONET/optical transport equipment (SONET-layer alarm status) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type slSonetAlarmSeverity into the Find box to locate it in the OID tree, then select it and click OK. The alarm severity. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the value is anything other than 'noAlarm', since that indicates the condition this object reports has changed to one worth investigating. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.4515smartopticsSL-NE-MIB
1.3.6.1.4.1.4515.1sitelightSL-NE-MIB
1.3.6.1.4.1.4515.1.6slSonetMibSL-SONET-MIB
Numeric OIDNameModule
1.3.6.1.4.1.4515.1.6.4slSonetAlarmMibSL-SONET-ALARM-MIB
1.3.6.1.4.1.4515.1.6.4.2slSonetAlarmTrapsSL-SONET-ALARM-MIB
1.3.6.1.4.1.4515.1.6.4.2.1slSonetAlarmSeveritySL-SONET-ALARM-MIB