SL-ESCON-MIB :: esconPortCurrentRxOctets

MIB Reference — IPNetwork Monitor · Updated September 21, 2026

All MIBs › SL-ESCON-MIB › esconPortCurrentRxOctets

esconPortCurrentRxOctets

Module: SL-ESCON-MIB

OID (symbolic): SL-ESCON-MIB::esconPortCurrentRxOctets

OID (numeric): 1.3.6.1.4.1.4515.1.1.5.1.2.1.1.2

Node type: OBJECT-TYPE

Type: Counter64

Access: read-only

Description: The total number of octets of data received during the current interval.

What is esconPortCurrentRxOctets?

The total number of octets received on this ESCON port during the current (still running) 15-minute interval. An admin watches this to gauge inbound throughput on the link.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4515.1.1.5.1.2.1.1.2
snmpwalk -v2c -c public <target> SL-ESCON-MIB::esconPortCurrentRxOctets

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.4515.1.1.5.1.2.1.1.2.1
snmpget -v2c -c public <target> SL-ESCON-MIB::esconPortCurrentRxOctets.1

Start monitoring Smartoptics SiteLight optical transport platform, ESCON interface module (link login/signal-loss statistics) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SL-ESCON-MIB::esconPortCurrentRxOctets OID value, configure state conditions and alerts, and monitor any Smartoptics SiteLight optical transport platform, ESCON interface module (link login/signal-loss statistics) from a single console.

How to Use in IPNetwork Monitor

Select a Smartoptics SiteLight optical transport platform, ESCON interface module (link login/signal-loss statistics) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type esconPortCurrentRxOctets into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The total number of octets of data received during the current interval. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter64-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.4515smartopticsSL-NE-MIB
1.3.6.1.4.1.4515.1sitelightSL-NE-MIB
1.3.6.1.4.1.4515.1.1slServiceSL-NE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.4515.1.1.5esconMIBSL-ESCON-MIB
1.3.6.1.4.1.4515.1.1.5.1esconMIBObjectsSL-ESCON-MIB
1.3.6.1.4.1.4515.1.1.5.1.2esconPmSL-ESCON-MIB
1.3.6.1.4.1.4515.1.1.5.1.2.1esconPortCurrentTableSL-ESCON-MIB
1.3.6.1.4.1.4515.1.1.5.1.2.1.1esconPortCurrentEntrySL-ESCON-MIB
1.3.6.1.4.1.4515.1.1.5.1.2.1.1.2esconPortCurrentRxOctetsSL-ESCON-MIB