| OID symbolic | OID numeric | Type | Access | Description |
| pmG828 | 1.3.6.1.4.1.3373.1103.11 | | | Perforfamce Monitoring according to ITU-T G.829 for Radio Link
and E1 Tributaries |
| INT pmG828MibVersion | 1.3.6.1.4.1.3373.1103.11.1 | INTEGER | read-only | Numerical version of this module.
The string version of this MIB have the following format:
XX.YY.ZZ
so, for example, the value 1 should be interpreted as 00.00.01
and the value 10001 should be interpreted as 01.00.01. |
| pmG828CounterTable | 1.3.6.1.4.1.3373.1103.11.2 | | not-accessible | Table with PmG828 records: one record for 1+0 configuration and two
record for 1+1 configuration. |
| pmG828CounterRecord | 1.3.6.1.4.1.3373.1103.11.2.1 | | not-accessible | PmG828Counter record. |
| I32 pmG828TPointId | 1.3.6.1.4.1.3373.1103.11.2.1.1 | Integer32 | read-only | This object identifies the Termination Point. |
| I32 pmG828CounterBlockId | 1.3.6.1.4.1.3373.1103.11.2.1.2 | Integer32 | read-only | This object identifies the counters block and the counter type
according to the following code:
1 Current Daily counters
2 Daily counters (Day before counters)
3 Current 15 minutes counters
4 15 minutes counters N. 1 (The most recent 15 minutes counters)
..............................................
n 15 minutes counters N. n
20 15 minutes counters N.16(The oldest 15 min.counters 4 hours before). |
| INT pmG828CounterBlockType | 1.3.6.1.4.1.3373.1103.11.2.1.3 | INTEGER | read-only | The type of the counter block. |
| INT pmG828CounterBlockStatus | 1.3.6.1.4.1.3373.1103.11.2.1.4 | INTEGER | read-only | Status of the block counter. |
| U32 pmG828CounterTimeStamp | 1.3.6.1.4.1.3373.1103.11.2.1.5 | Unsigned32 | read-only | The object is the time when the performance record is closed reported
as the second number since 1-Gen-1970. |
| C32 pmG828BBECounterEx | 1.3.6.1.4.1.3373.1103.11.2.1.6 | Counter32 | read-only | G828 BBE counter. |
| C32 pmG828ESCounter | 1.3.6.1.4.1.3373.1103.11.2.1.7 | Counter32 | read-only | G828 Es counter. |
| C32 pmG828SESCounter | 1.3.6.1.4.1.3373.1103.11.2.1.8 | Counter32 | read-only | G828 SES counter. |
| C32 pmG828UASCounter | 1.3.6.1.4.1.3373.1103.11.2.1.9 | Counter32 | read-only | G828 UAS counter. |
| C32 pmG828SEPCounter | 1.3.6.1.4.1.3373.1103.11.2.1.10 | Counter32 | read-only | G828 SEP counter. |
| pmG828TpClassTable | 1.3.6.1.4.1.3373.1103.11.3 | | not-accessible | Table with PmG828TpClass records: one record for 1+0 configuration and
two record for 1+1 configuration. |
| pmG828TpClassRecord | 1.3.6.1.4.1.3373.1103.11.3.1 | | not-accessible | PmG828TpClass record. |
| I32 pmG828TpClassId | 1.3.6.1.4.1.3373.1103.11.3.1.1 | Integer32 | read-only | This object identifies the Termination Point. |
| INT pmG828TpClassStartStop | 1.3.6.1.4.1.3373.1103.11.3.1.2 | INTEGER | read-create | This object is used to start and to stop the Perfomance Monitoring
counter evaluation. |
| STR pmG828TpClassLabel | 1.3.6.1.4.1.3373.1103.11.3.1.3 | DisplayString | read-only | ASCII string used to identify the Tp class:
for example:
pmG828TpClassBranchId = 1 label = Radio 1
pmG828TpClassBranchId = 2 label = Radio 2
pmG828TpClassBranchId = 3 label = Radio(switched)
pmG828TpClassBranchId = 4 label = Trib E1 line side
pmG828TpClassBranchId = 5 label = Trib E1 radio side. |
| U32 pmG828TpClassTimeStamp | 1.3.6.1.4.1.3373.1103.11.3.1.4 | Unsigned32 | read-only | |
| ALA pmG828TpClass15MEsAlarm | 1.3.6.1.4.1.3373.1103.11.3.1.5 | AlarmStatus | read-only | 15 minutes ES threshold cross alarm with associated severity. |
| ALA pmG828TpClass15MSesAlarm | 1.3.6.1.4.1.3373.1103.11.3.1.6 | AlarmStatus | read-only | 15 minutes SES threshold cross alarm with associated severity. |
| ALA pmG828TpClass15MSepAlarm | 1.3.6.1.4.1.3373.1103.11.3.1.7 | AlarmStatus | read-only | 15 minutes SEP threshold cross alarm with associated severity. |
| ALA pmG828TpClass24HEsAlarm | 1.3.6.1.4.1.3373.1103.11.3.1.8 | AlarmStatus | read-only | Daily ES threshold cross alarm with associated severity. |
| ALA pmG828TpClass24HSesAlarm | 1.3.6.1.4.1.3373.1103.11.3.1.9 | AlarmStatus | read-only | Daily SES threshold cross alarm with associated severity. |
| ALA pmG828TpClass24HSepAlarm | 1.3.6.1.4.1.3373.1103.11.3.1.10 | AlarmStatus | read-only | Daily SEP threshold cross alarm with associated severity. |
| ALA pmG828TpClassUasAlarm | 1.3.6.1.4.1.3373.1103.11.3.1.11 | AlarmStatus | read-only | UAS alarm with associated severity. |
| I32 pmG828TpClass15MEsThreshold | 1.3.6.1.4.1.3373.1103.11.3.1.12 | Integer32 | read-create | Number of ES within 15 minutes to set pmG828TpClass15MEsAlarm
(zero value disables the alarm). |
| I32 pmG828TpClass15MSesThreshold | 1.3.6.1.4.1.3373.1103.11.3.1.13 | Integer32 | read-create | Number of SES within 15 minutes to set pmG828TpClass15MSesAlarm
(zero value disables the alarm). |
| I32 pmG828TpClass15MSepThreshold | 1.3.6.1.4.1.3373.1103.11.3.1.14 | Integer32 | read-create | Number of SEP within 15 minutes to set pmG828TpClass15MSepAlarm
(zero value disables the alarm). |
| I32 pmG828TpClass24HEsThreshold | 1.3.6.1.4.1.3373.1103.11.3.1.15 | Integer32 | read-create | Number of ES within one day to set pmG828TpClass24HEsAlarm
(zero value disables the alarm). |
| I32 pmG828TpClass24HSesThreshold | 1.3.6.1.4.1.3373.1103.11.3.1.16 | Integer32 | read-create | Number of SES within one day to set pmG828TpClass24HSesAlarm
(zero value disables the alarm). |
| I32 pmG828TpClass24HSepThreshold | 1.3.6.1.4.1.3373.1103.11.3.1.17 | Integer32 | read-create | Number of SEP within one day to set pmG828TpClass24HSepAlarm
(zero value disables the alarm). |
| ROW pmG828TpClassRowStatus | 1.3.6.1.4.1.3373.1103.11.3.1.18 | RowStatus | read-create | Status of this row of pmRxPwrTpClass. |
| pmG828TpMaintTable | 1.3.6.1.4.1.3373.1103.11.4 | | not-accessible | Table with Command for maintenance of Termination Point.
Objects in this table is not persistent. An Instance of this
table is created on creation of pmG828TpClassTable |
| pmG828TpMaintRecord | 1.3.6.1.4.1.3373.1103.11.4.1 | | not-accessible | PmG828 Termination Point Maintenance record. |
| INT pmG828TpMaintCounterClear | 1.3.6.1.4.1.3373.1103.11.4.1.1 | INTEGER | read-write | This object is used to clear the Perfomance Monitoring counters. |
| INT pmG828TpMaintAlarmClear | 1.3.6.1.4.1.3373.1103.11.4.1.2 | INTEGER | read-write | This object is used to clear the Perfomance Monitoring threshold cross alarms. |
| I32 pmG828NSesSetUAS | 1.3.6.1.4.1.3373.1103.11.5 | Integer32 | read-write | Number of SES (according G.828) to set UAS. |
| I32 pmG828NSesResetUAS | 1.3.6.1.4.1.3373.1103.11.6 | Integer32 | read-write | Number of seconds whitout errors (according G.828) to reset UAS. |
| ALA pmG828TpClass15MEsAlarmSeverityCode | 1.3.6.1.4.1.3373.1103.11.7 | AlarmSeverityCode | read-write | Defines the severity associated to the pmG828TpClass15MEsAlarm and
enables/disables the trap generation on status change event. |
| ALA pmG828TpClass15MSesAlarmSeverityCode | 1.3.6.1.4.1.3373.1103.11.8 | AlarmSeverityCode | read-write | Define the severity associated to the pmG828TpClass15MSesAlarm and
enables/disables the trap generation on status change event. |
| ALA pmG828TpClass24HEsAlarmSeverityCode | 1.3.6.1.4.1.3373.1103.11.9 | AlarmSeverityCode | read-write | Define the severity associated to the pmG828TpClass15MEsAlarm and
enables/disables the trap generation on status change event. |
| ALA pmG828TpClass24HSesAlarmSeverityCode | 1.3.6.1.4.1.3373.1103.11.10 | AlarmSeverityCode | read-write | Define the severity associated to the pmG828TpClass15MSesAlarm and
enables/disables the trap generation on status change event. |
| ALA pmG828TpClassUASAlarmSeverityCode | 1.3.6.1.4.1.3373.1103.11.11 | AlarmSeverityCode | read-write | Define the severity associated to the pmG828TpClassUASAlarm and
enables/disables the trap generation on status change event. |
| ALA pmG828TpClass15MSepAlarmSeverityCode | 1.3.6.1.4.1.3373.1103.11.12 | AlarmSeverityCode | read-write | Define the severity associated to the pmG828TpClass15MSepAlarm and
enables/disables the trap generation on status change event. |
| ALA pmG828TpClass24HSepAlarmSeverityCode | 1.3.6.1.4.1.3373.1103.11.13 | AlarmSeverityCode | read-write | Define the severity associated to the pmG828TpClass24HSepAlarm and
enables/disables the trap generation on status change event. |