SHE-SELT-MIB :: sheSeltTestRequestControlReqFDRCollectionNumAverage

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › SHE-SELT-MIB › sheSeltTestRequestControlReqFDRCollectionNumAverage

sheSeltTestRequestControlReqFDRCollectionNumAverage

Module: SHE-SELT-MIB

OID (symbolic): SHE-SELT-MIB::sheSeltTestRequestControlReqFDRCollectionNumAverage

OID (numeric): 1.3.6.1.4.1.231.7.1.2.2.1.23.4.9

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-write

Description: This parameter is specific for Infineon line card, but not for Conexant line card. This parameter is to set the number of average for FDR Data Collection when sheSeltTestRequestControlReqFDRCollectionEnable is Enable(1). When sheSeltTestRequestControlReqFDRCollectionEnable is Disable(0), this one will be igored. The range of this one is [1, 65535], and the default value is 1024. With this default number of averages, a single data collection will take approximately 90 seconds.

What is sheSeltTestRequestControlReqFDRCollectionNumAverage?

This read-write Unsigned32 (1-65535, default 1024) sets how many samples to average when FDR data collection is enabled on an Infineon line card SELT test; it is ignored when FDR collection is disabled.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.231.7.1.2.2.1.23.4.9
snmpwalk -v2c -c public <target> SHE-SELT-MIB::sheSeltTestRequestControlReqFDRCollectionNumAverage

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.231.7.1.2.2.1.23.4.9.1
snmpget -v2c -c public <target> SHE-SELT-MIB::sheSeltTestRequestControlReqFDRCollectionNumAverage.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.231.7.1.2.2.1.23.4.9.1 i <value>

Start monitoring Nokia Siemens Networks SHE/hiX-series DSLAM access node (Single-Ended Line Test command/status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SHE-SELT-MIB::sheSeltTestRequestControlReqFDRCollectionNumAverage OID value, configure state conditions and alerts, and monitor any Nokia Siemens Networks SHE/hiX-series DSLAM access node (Single-Ended Line Test command/status) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.231sniAN-MIB
1.3.6.1.4.1.231.7siemensUnitsAN-MIB
1.3.6.1.4.1.231.7.1oenProductMibsAN-MIB
1.3.6.1.4.1.231.7.1.2anAN-MIB
1.3.6.1.4.1.231.7.1.2.2ppeAN-SHE-MIB
1.3.6.1.4.1.231.7.1.2.2.1sheAN-SHE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.231.7.1.2.2.1.23sheSeltSHE-SELT-MIB
1.3.6.1.4.1.231.7.1.2.2.1.23.4sheSeltTestRequestControlSHE-SELT-MIB
1.3.6.1.4.1.231.7.1.2.2.1.23.4.9sheSeltTestRequestControlReqFDRCollectionNumAverageSHE-SELT-MIB