All MIBs › SHE-PM-DR-MIB › shePmDrControlResult
shePmDrControlResult
Module: SHE-PM-DR-MIB
OID (symbolic): SHE-PM-DR-MIB::shePmDrControlResult
OID (numeric): 1.3.6.1.4.1.231.7.1.2.2.1.30.2.1.1
Node type: NOTIFICATION-TYPE
Description: Notification sent at the end of long running command. The possible values of shePmDrControlReqResult are: wrongIpAddress(2), -- IP address of FTP servre is incorrect wrongUserPassword(3), -- The user name or password is wrong permissionDenied(4), -- The user name has no permission to create dir/file commandSucceeded(37)
Examples
Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):
snmptrap -v2c -c public <manager> '' SHE-PM-DR-MIB::shePmDrControlResult snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.231.7.1.2.2.1.30.2.1.1
Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):
snmptrapd -f -Lo -c /dev/null authCommunity log public
Example snmptrapd log entry:
zoo11-linux.zoo [UDP: [192.168.30.111]:61281->[192.168.30.10]:162]: DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (502241633) 58 days, 3:06:56.33 SNMPv2-MIB::snmpTrapOID.0 = OID: SHE-PM-DR-MIB::shePmDrControlResult
Start monitoring Nokia Siemens Networks SHE/hiX-series DSLAM access node (performance-data FTP retrieval scheduling/status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SHE-PM-DR-MIB::shePmDrControlResult OID value, configure state conditions and alerts, and monitor any Nokia Siemens Networks SHE/hiX-series DSLAM access node (performance-data FTP retrieval scheduling/status) from a single console.
OID Breakdown
Upper-level ancestors (12 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.231 | sni | AN-MIB |
| 1.3.6.1.4.1.231.7 | siemensUnits | AN-MIB |
| 1.3.6.1.4.1.231.7.1 | oenProductMibs | AN-MIB |
| 1.3.6.1.4.1.231.7.1.2 | an | AN-MIB |
| 1.3.6.1.4.1.231.7.1.2.2 | ppe | AN-SHE-MIB |
| 1.3.6.1.4.1.231.7.1.2.2.1 | she | AN-SHE-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.231.7.1.2.2.1.30 | shePmDrMib | SHE-PM-DR-MIB |
| 1.3.6.1.4.1.231.7.1.2.2.1.30.2 | shePmDrNotifications | SHE-PM-DR-MIB |
| 1.3.6.1.4.1.231.7.1.2.2.1.30.2.1 | shePmDrEvents | SHE-PM-DR-MIB |
| 1.3.6.1.4.1.231.7.1.2.2.1.30.2.1.1 | shePmDrControlResult | SHE-PM-DR-MIB |