SHE-MTA-MIB :: sheMtaCtrlControlReq

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SHE-MTA-MIB › sheMtaCtrlControlReq

sheMtaCtrlControlReq

Module: SHE-MTA-MIB

OID (symbolic): SHE-MTA-MIB::sheMtaCtrlControlReq

OID (numeric): 1.3.6.1.4.1.231.7.1.2.2.1.10.1.1

Node type: OBJECT-TYPE

Type: SheMtaControlRequestType

Access: read-write

Description: Controls the metallic test access (MTA) feature (activate or deactivate) at ADSL line interfaces. MTA is provided only for ADSL lines and for one line at a given time. The plugin unit IU must be unlocked. If MTA has been activated for a line the command command mtaActivate implicitly deactivates MTA for that line and activates it on the new line. MTA is service affecting. The command mtaDeactivate terminates MTA. MTA is terminated by the DSLAM autonomously if the IU will be locked or performs a restart.

What is sheMtaCtrlControlReq?

This object activates or deactivates metallic test access (MTA) on an ADSL line interface, a service-affecting feature usable on only one line at a time and requiring the plugin unit to be unlocked. An admin issues mtaActivate to run copper-line diagnostics on a subscriber line, implicitly deactivating MTA on any other line first, and issues mtaDeactivate to end the test; the DSLAM also auto-terminates MTA if the line card is locked or restarts. For example, a technician troubleshooting a noisy ADSL line sets this to mtaActivate to route it through the test access relay for line-fault measurement.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.231.7.1.2.2.1.10.1.1
snmpwalk -v2c -c public <target> SHE-MTA-MIB::sheMtaCtrlControlReq

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.231.7.1.2.2.1.10.1.1.1
snmpget -v2c -c public <target> SHE-MTA-MIB::sheMtaCtrlControlReq.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.231.7.1.2.2.1.10.1.1.1 s <value>

Start monitoring Nokia Siemens Networks SHE DSLAM (subscriber-line maintenance test/activation command status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SHE-MTA-MIB::sheMtaCtrlControlReq OID value, configure state conditions and alerts, and monitor any Nokia Siemens Networks SHE DSLAM (subscriber-line maintenance test/activation command status) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.231sniAN-MIB
1.3.6.1.4.1.231.7siemensUnitsAN-MIB
1.3.6.1.4.1.231.7.1oenProductMibsAN-MIB
1.3.6.1.4.1.231.7.1.2anAN-MIB
1.3.6.1.4.1.231.7.1.2.2ppeAN-SHE-MIB
1.3.6.1.4.1.231.7.1.2.2.1sheAN-SHE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.231.7.1.2.2.1.10sheMtaSHE-MTA-MIB
1.3.6.1.4.1.231.7.1.2.2.1.10.1sheMtaControlSHE-MTA-MIB
1.3.6.1.4.1.231.7.1.2.2.1.10.1.1sheMtaCtrlControlReqSHE-MTA-MIB