All MIBs › SHE-GBOND-MIB › sheGBondTargetUpDataRate
sheGBondTargetUpDataRate
Module: SHE-GBOND-MIB
OID (symbolic): SHE-GBOND-MIB::sheGBondTargetUpDataRate
OID (numeric): 1.3.6.1.4.1.231.7.1.2.2.1.26.1.1.3.1.2
Node type: OBJECT-TYPE
Type: Unsigned32
Access: read-only
Description: A desired G.Bond port Data Rate in the upstream direction, in Kbps, to be achieved during initialization, under restrictions placed upon the member BCEs by their respective configuration settings. This object represents a sum of individual BCE upstream data rates, modified to compensate for fragmentation and encapsulation overhead (e.g. for an Ethernet service, the target data rate of 10Mbps SHALL allow lossless transmission of full-duplex 10Mbps Ethernet frame stream with minimal inter-frame gap). Note that the target upstream data rate may not be achieved during initialization (e.g. due to unavailability of required BCEs) or the initial bandwidth could deteriorate, so that the actual upstream data rate (sheGBondUpDataRate) could be less than sheGBondTargetUpDataRate.
The value between 1 and 1000000 indicates that the total upstream data rate of the G.Bond port after initialization SHALL be equal to the target data rate or less, if the target upstream data rate cannot be achieved under the restrictions configured for BCEs. In case the copper environment allows to achieve higher upstream data rate than that specified by this object, the excess capability SHALL be either converted to additional SNR margin or reclaimed by minimizing transmit power.
The value of 9999999 means that the target data rate is not fixed and SHALL be set to the maximum attainable rate during initialization (Best Effort), under specified spectral restrictions and with desired SNR Margin per BCE.
This object is valid for the -O subtype G.Bond ports and irrelevant for the -R subtypes.
Changing of the Target Upstream Data Rate MUST be performed when the link is Down. Attempts to change this object MUST be rejected (In case of SNMP with the error inconsistentValue), if the link is Up or Initializing.
This object MUST be maintained in a persistent manner.
NOTE: Not configurable for VDSL2 based GBOND interfaces.
What is sheGBondTargetUpDataRate?
This OID configures the desired upstream data rate (in Kbps, 1-1000000) this G.Bond port should try to reach during initialization, or 9999999 to mean best-effort/maximum attainable rate; it only applies to -O subtype ports, can't be changed for VDSL2-based bonds, and can only be changed while the link is down. Admins set this when provisioning a new bonding group to cap or leave open the aggregate upstream throughput target.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.231.7.1.2.2.1.26.1.1.3.1.2 snmpwalk -v2c -c public <target> SHE-GBOND-MIB::sheGBondTargetUpDataRate
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.231.7.1.2.2.1.26.1.1.3.1.2.1 snmpget -v2c -c public <target> SHE-GBOND-MIB::sheGBondTargetUpDataRate.1
Start monitoring Nokia Siemens Networks SHE DSLAM, fixed-line broadband access equipment (multi-pair bonded xDSL status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SHE-GBOND-MIB::sheGBondTargetUpDataRate OID value, configure state conditions and alerts, and monitor any Nokia Siemens Networks SHE DSLAM, fixed-line broadband access equipment (multi-pair bonded xDSL status) from a single console.
OID Breakdown
Upper-level ancestors (12 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.231 | sni | AN-MIB |
| 1.3.6.1.4.1.231.7 | siemensUnits | AN-MIB |
| 1.3.6.1.4.1.231.7.1 | oenProductMibs | AN-MIB |
| 1.3.6.1.4.1.231.7.1.2 | an | AN-MIB |
| 1.3.6.1.4.1.231.7.1.2.2 | ppe | AN-SHE-MIB |
| 1.3.6.1.4.1.231.7.1.2.2.1 | she | AN-SHE-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.231.7.1.2.2.1.26 | sheGBondMIB | SHE-GBOND-MIB |
| 1.3.6.1.4.1.231.7.1.2.2.1.26.1 | sheGBondObjects | SHE-GBOND-MIB |
| 1.3.6.1.4.1.231.7.1.2.2.1.26.1.1 | sheGBondPort | SHE-GBOND-MIB |
| 1.3.6.1.4.1.231.7.1.2.2.1.26.1.1.3 | sheGBondPortConfTable | SHE-GBOND-MIB |
| 1.3.6.1.4.1.231.7.1.2.2.1.26.1.1.3.1 | sheGBondPortConfEntry | SHE-GBOND-MIB |
| 1.3.6.1.4.1.231.7.1.2.2.1.26.1.1.3.1.2 | sheGBondTargetUpDataRate | SHE-GBOND-MIB |