Module: SHE-ETHERNET-MIB

OID (symbolic): SHE-ETHERNET-MIB::sheEthernetPortControlSwitchoverOnLinkDown

OID (numeric): 1.3.6.1.4.1.231.7.1.2.2.1.5.1.3.18

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-write

Description: A given port's link status is monitored. When link down for the port is detected, switchover from an active board to a standby board is performed.

What is sheEthernetPortControlSwitchoverOnLinkDown?

This read-write TruthValue sets whether link-down detection on the targeted port should trigger a board switchover, via the setEthernetPortSwitchoverOnLinkDown control command. An admin writes this to wire (or unwire) a specific port's link status into the active/standby board protection-switchover logic. Setting sheEthernetPortControlSwitchoverOnLinkDown to true and submitting the control command means a link failure on this port alone can now trigger a switchover to the standby board.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.231.7.1.2.2.1.5.1.3.18
snmpwalk -v2c -c public <target> SHE-ETHERNET-MIB::sheEthernetPortControlSwitchoverOnLinkDown

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.231.7.1.2.2.1.5.1.3.18.1
snmpget -v2c -c public <target> SHE-ETHERNET-MIB::sheEthernetPortControlSwitchoverOnLinkDown.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.231.7.1.2.2.1.5.1.3.18.1 s <value>

Start monitoring Nokia Siemens Networks SHE DSLAM (Ethernet uplink config, EtherLike error counters, laser status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SHE-ETHERNET-MIB::sheEthernetPortControlSwitchoverOnLinkDown OID value, configure state conditions and alerts, and monitor any Nokia Siemens Networks SHE DSLAM (Ethernet uplink config, EtherLike error counters, laser status) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.231sniAN-MIB
1.3.6.1.4.1.231.7siemensUnitsAN-MIB
1.3.6.1.4.1.231.7.1oenProductMibsAN-MIB
1.3.6.1.4.1.231.7.1.2anAN-MIB
1.3.6.1.4.1.231.7.1.2.2ppeAN-SHE-MIB
1.3.6.1.4.1.231.7.1.2.2.1sheAN-SHE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.231.7.1.2.2.1.5sheEthernetMibSHE-ETHERNET-MIB
1.3.6.1.4.1.231.7.1.2.2.1.5.1sheEthernetSHE-ETHERNET-MIB
1.3.6.1.4.1.231.7.1.2.2.1.5.1.3sheEthernetPortControlSHE-ETHERNET-MIB
1.3.6.1.4.1.231.7.1.2.2.1.5.1.3.18sheEthernetPortControlSwitchoverOnLinkDownSHE-ETHERNET-MIB