All MIBs › SHE-ETHERNET-MIB › sheEthernetPortControlStandbyLaserOff
sheEthernetPortControlStandbyLaserOff
Module: SHE-ETHERNET-MIB
OID (symbolic): SHE-ETHERNET-MIB::sheEthernetPortControlStandbyLaserOff
OID (numeric): 1.3.6.1.4.1.231.7.1.2.2.1.5.1.3.17
Node type: OBJECT-TYPE
Type: SheEnableType
Access: read-write
Description: .
What is sheEthernetPortControlStandbyLaserOff?
This read-write SheEnableType sets whether the standby laser-off feature should be enabled or disabled for the targeted port via the setEthernetPortStandbyLaserOff control command. An admin writes this to configure whether this port's optical transmitter powers down its laser while its board is in standby. Setting sheEthernetPortControlStandbyLaserOff to enable and submitting the control command turns on standby laser shutdown for the targeted port, updating sheEthernetPortStandbyLaserOff accordingly.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.231.7.1.2.2.1.5.1.3.17 snmpwalk -v2c -c public <target> SHE-ETHERNET-MIB::sheEthernetPortControlStandbyLaserOff
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.231.7.1.2.2.1.5.1.3.17.1 snmpget -v2c -c public <target> SHE-ETHERNET-MIB::sheEthernetPortControlStandbyLaserOff.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.231.7.1.2.2.1.5.1.3.17.1 s <value>
Start monitoring Nokia Siemens Networks SHE DSLAM (Ethernet uplink config, EtherLike error counters, laser status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SHE-ETHERNET-MIB::sheEthernetPortControlStandbyLaserOff OID value, configure state conditions and alerts, and monitor any Nokia Siemens Networks SHE DSLAM (Ethernet uplink config, EtherLike error counters, laser status) from a single console.
OID Breakdown
Upper-level ancestors (12 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.231 | sni | AN-MIB |
| 1.3.6.1.4.1.231.7 | siemensUnits | AN-MIB |
| 1.3.6.1.4.1.231.7.1 | oenProductMibs | AN-MIB |
| 1.3.6.1.4.1.231.7.1.2 | an | AN-MIB |
| 1.3.6.1.4.1.231.7.1.2.2 | ppe | AN-SHE-MIB |
| 1.3.6.1.4.1.231.7.1.2.2.1 | she | AN-SHE-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.231.7.1.2.2.1.5 | sheEthernetMib | SHE-ETHERNET-MIB |
| 1.3.6.1.4.1.231.7.1.2.2.1.5.1 | sheEthernet | SHE-ETHERNET-MIB |
| 1.3.6.1.4.1.231.7.1.2.2.1.5.1.3 | sheEthernetPortControl | SHE-ETHERNET-MIB |
| 1.3.6.1.4.1.231.7.1.2.2.1.5.1.3.17 | sheEthernetPortControlStandbyLaserOff | SHE-ETHERNET-MIB |