SCTE-HMS-HE-COMMON-MIB :: heCommonTemperature

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › SCTE-HMS-HE-COMMON-MIB › heCommonTemperature

heCommonTemperature

Module: SCTE-HMS-HE-COMMON-MIB

OID (symbolic): SCTE-HMS-HE-COMMON-MIB::heCommonTemperature

OID (numeric): 1.3.6.1.4.1.5591.1.11.2.1.1.1.1.1.1.2

Node type: OBJECT-TYPE

Type: HeTenthCentigrade

Access: read-only

Description: Temperature measured inside the headend equipment.

This object must provide for the alarm management capabilities with a corresponding entry in the propertyTable of SCTE-HMS-PROPERTY-MIB (HMS026).

An alarm shall be recorded as an entry in the currentAlarmTable of SCTE-HMS-PROPERTY-MIB (HMS026).

A log record shall be added as an entry in the heCommonLogTable.

An heCommonAlarmEvent notification shall be sent.

What is heCommonTemperature?

This read-only value reports the temperature measured inside the headend equipment, and per the source DESCRIPTION is wired into the SCTE-HMS-PROPERTY-MIB alarm framework so a threshold crossing generates a log entry, a current-alarm-table entry, and an heCommonAlarmEvent notification. An admin monitors it to catch overheating headend equipment before it fails, relying on the associated alarm and logging infrastructure to be proactively notified rather than needing to poll constantly. For example, a technician responding to an heCommonAlarmEvent trap would check this object's current value to see how far the internal temperature has risen above its configured threshold.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5591.1.11.2.1.1.1.1.1.1.2
snmpwalk -v2c -c public <target> SCTE-HMS-HE-COMMON-MIB::heCommonTemperature

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5591.1.11.2.1.1.1.1.1.1.2.1
snmpget -v2c -c public <target> SCTE-HMS-HE-COMMON-MIB::heCommonTemperature.1

Start monitoring vendor-neutral, SCTE HMS standards-based MIB, cable headend/hub-site optical and RF equipment (temperature/alarm log) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SCTE-HMS-HE-COMMON-MIB::heCommonTemperature OID value, configure state conditions and alerts, and monitor any vendor-neutral, SCTE HMS standards-based MIB, cable headend/hub-site optical and RF equipment (temperature/alarm log) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.5591scteRootSCTE-ROOT
1.3.6.1.4.1.5591.1scteHmsTreeSCTE-ROOT
1.3.6.1.4.1.5591.1.11insidePlantIdentSCTE-HMS-ROOTS
1.3.6.1.4.1.5591.1.11.2heBaseIdentSCTE-HMS-HEADENDIDENT-MIB
1.3.6.1.4.1.5591.1.11.2.1heCommonSCTE-HMS-HEADENDIDENT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.5591.1.11.2.1.1heCommonMibSCTE-HMS-HE-COMMON-MIB
1.3.6.1.4.1.5591.1.11.2.1.1.1heCommonObjectsSCTE-HMS-HE-COMMON-MIB
1.3.6.1.4.1.5591.1.11.2.1.1.1.1heCommonParamsSCTE-HMS-HE-COMMON-MIB
1.3.6.1.4.1.5591.1.11.2.1.1.1.1.1heCommonTableSCTE-HMS-HE-COMMON-MIB
1.3.6.1.4.1.5591.1.11.2.1.1.1.1.1.1heCommonEntrySCTE-HMS-HE-COMMON-MIB
1.3.6.1.4.1.5591.1.11.2.1.1.1.1.1.1.2heCommonTemperatureSCTE-HMS-HE-COMMON-MIB