All MIBs › SCA-X25EXT-MIB › x25extCircuitTimeout
x25extCircuitTimeout
Module: SCA-X25EXT-MIB
OID (symbolic): SCA-X25EXT-MIB::x25extCircuitTimeout
OID (numeric): 1.3.6.1.4.1.208.51.1.1.1.6
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Seconds left before timeout of the current state. If a call request is sent but no reply received x25extCircuitTimeout will show how many seconds remains before the call request is retransmitted. If the link is up but the current window is 0 x25extCircuitTimeout will show how many seconds remains before the link is reset and x25extCircuitOutFlowStuckResets is incremented.
What is x25extCircuitTimeout?
This object reports the seconds remaining before a timeout of the circuit's current state; if a call request was sent but no reply received, it shows the countdown to retransmission, and if the link is up with a zero window it counts down to a link reset that also increments x25extCircuitOutFlowStuckResets. Admins watch it while diagnosing a stuck or slow-to-connect X.25 circuit to understand what the device is about to do next. A x25extCircuitTimeout nearing zero on a circuit stuck at zero window warns the admin a flow-control reset is imminent.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.208.51.1.1.1.6 snmpwalk -v2c -c public <target> SCA-X25EXT-MIB::x25extCircuitTimeout
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.208.51.1.1.1.6.1 snmpget -v2c -c public <target> SCA-X25EXT-MIB::x25extCircuitTimeout.1
Start monitoring Securicor X.25 WAN router/gateway (per-circuit X.25 configuration/reset counters) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SCA-X25EXT-MIB::x25extCircuitTimeout OID value, configure state conditions and alerts, and monitor any Securicor X.25 WAN router/gateway (per-circuit X.25 configuration/reset counters) from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.208 | scanet | SCANET-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.208.51 | x25ext | SCA-X25EXT-MIB |
| 1.3.6.1.4.1.208.51.1 | x25extCircuit | SCA-X25EXT-MIB |
| 1.3.6.1.4.1.208.51.1.1 | x25extCircuitTable | SCA-X25EXT-MIB |
| 1.3.6.1.4.1.208.51.1.1.1 | x25extCircuitEntry | SCA-X25EXT-MIB |
| 1.3.6.1.4.1.208.51.1.1.1.6 | x25extCircuitTimeout | SCA-X25EXT-MIB |