SCA-MPLINK-MIB :: acceptIncomingCalls1

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsSCA-MPLINK-MIBacceptIncomingCalls1

acceptIncomingCalls1

Module: SCA-MPLINK-MIB

OID (symbolic): SCA-MPLINK-MIB::acceptIncomingCalls1

OID (numeric): 1.3.6.1.4.1.208.24.3.1.1.8

Node type: OBJECT-TYPE

Type: OffOn

Access: read-write

What is acceptIncomingCalls1?

Controls whether this WAN link is allowed to accept incoming dial calls. Admins turn this off on links meant to be outbound-only, such as a backup link that should only be dialed by this device, never dialed into.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.208.24.3.1.1.8
snmpwalk -v2c -c public <target> SCA-MPLINK-MIB::acceptIncomingCalls1

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.208.24.3.1.1.8.1
snmpget -v2c -c public <target> SCA-MPLINK-MIB::acceptIncomingCalls1.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.208.24.3.1.1.8.1 s <value>

Start monitoring Securicor SCANET multipoint WAN routers (multipoint service/LAN/WAN link configuration and counters) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SCA-MPLINK-MIB::acceptIncomingCalls1 OID value, configure state conditions and alerts, and monitor any Securicor SCANET multipoint WAN routers (multipoint service/LAN/WAN link configuration and counters) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.208scanetSCANET-MIB
Numeric OIDNameModule
1.3.6.1.4.1.208.24mplkSCA-MPLINK-MIB
1.3.6.1.4.1.208.24.3wanSpecificSCA-MPLINK-MIB
1.3.6.1.4.1.208.24.3.1wanTableSCA-MPLINK-MIB
1.3.6.1.4.1.208.24.3.1.1wanEntrySCA-MPLINK-MIB
1.3.6.1.4.1.208.24.3.1.1.8acceptIncomingCalls1SCA-MPLINK-MIB