SC5520-MIB :: sc5520DiagRemLoopWithSelf

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsSC5520-MIBsc5520DiagRemLoopWithSelf

sc5520DiagRemLoopWithSelf

Module: SC5520-MIB

OID (symbolic): SC5520-MIB::sc5520DiagRemLoopWithSelf

OID (numeric): 1.3.6.1.4.1.498.8.3.7.1.7

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: To initiate a Remoteloop with Selftest SET this object and specifiy a blocksize. The remote unit will go into remoteloop and the master (the sc5520) unit will go into Selftest. The sc5520 transmits an in-band command to its remote DSU, directing the remote to loop received signals back onto the network. The DSE is configurable to send (and accept) either a V.54 or a PN 127 remote loop command. The remote DSU must be configured to accept the same command the DSE transmits. The sc5520 enables its internal Test Pattern Generator to provide the signal for the Remote Loop and enables its Test Pattern Checker to verify the signal. The DSE is isolated from its DTE while the Test Pattern Generator and Checker are enabled. The blocksize indicates the number of blocks the Selftest pattern generator will run. There are 1000 bits/block. Emuns 3 through 10 are write only. If option Remlooptimeout is enabled then the maximum test time is 10 minutes otherwise block size time is used. The only valid responses to a READ are remoteloopOn(2) or remoteloopOff(1). This test will terminate after the specified number of blocks have been run. Reading test results via the sc5520DiagBitErrors or sc5520DiagBlockErrors objects while the test is running will cause the test to terminate prematurely and render the results invalid. Test results should be read only after the test is completed and are available from the master (sc5520) unit. The current Test Status can be obtained by reading the sc5520DiagTestStatus object on the master unit, reading test status on the remote unit may interfere with the diagonostic test pattern and cause errors. This test can also be terminated by seting the nms520DiagTestReset object.

What is sc5520DiagRemLoopWithSelf?

Setting this to a blocksize value sends an in-band command telling the remote DSU to loop back while this unit runs an internal self-test pattern for that many 1000-bit blocks; status reads back as remoteloopOn(2)/remoteloopOff(1), and results are read from sc5520DiagBitErrors/sc5520DiagBlockErrors once the test completes.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.498.8.3.7.1.7
snmpwalk -v2c -c public <target> SC5520-MIB::sc5520DiagRemLoopWithSelf

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.498.8.3.7.1.7.1
snmpget -v2c -c public <target> SC5520-MIB::sc5520DiagRemLoopWithSelf.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.498.8.3.7.1.7.1 i <value>

Start monitoring General DataComm SC5520 DSU/CSU (loopback/DTE-interface configuration) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SC5520-MIB::sc5520DiagRemLoopWithSelf OID value, configure state conditions and alerts, and monitor any General DataComm SC5520 DSU/CSU (loopback/DTE-interface configuration) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.498gdcGDC7616-MIB
1.3.6.1.4.1.498.8dsuDDS-MIB
Numeric OIDNameModule
1.3.6.1.4.1.498.8.3sc5520SC5520-MIB
1.3.6.1.4.1.498.8.3.7sc5520ExcDiagTableSC5520-MIB
1.3.6.1.4.1.498.8.3.7.1sc5520ExcDiagEntrySC5520-MIB
1.3.6.1.4.1.498.8.3.7.1.7sc5520DiagRemLoopWithSelfSC5520-MIB