All MIBs › SC5520-MIB › sc5520DiagExtRemoteLoop
sc5520DiagExtRemoteLoop
Module: SC5520-MIB
OID (symbolic): SC5520-MIB::sc5520DiagExtRemoteLoop
OID (numeric): 1.3.6.1.4.1.498.8.3.7.1.6
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Point to Point Application only. To initiate a Remoteloop test with no Selftest SET this object and specifiy external. The sc5520 DSE transmitt an in-band command to its remote DSU, directing the remote to loop received signals back onto the network. The DSE is configurable to send (and accept) either a V.54 or a PN127 remote loop command. The remote DSU must be configured to accept the same command the DSE transmits. Emun external(3) is write only. The only valid response to a READ is remoteloopOn(2) or remoteloopOff(1). To halt this test you must SET the sc5520DiagTestReset object unless option RemLoopTimeOut is enabled. If enable maximum test time is 10 minutes. Reading test results via the sc5520DiagBitErrors or sc5520DiagBlockErrors objects while the test is running will also cause the test to terminate. There are no test results associated with this test. Reading test status on the remote unit via nms520DiagTestStatus may interfere with the diagonostic test pattern generated from the terminal equipment. The Remote Loop Function is for use ONLY on point to point links.
What is sc5520DiagExtRemoteLoop?
Point-to-point only: setting this to external(3) sends an in-band V.54 or PN127 command telling the remote DSU to loop received signals back onto the network, with no local self-test pattern; status reads back as remoteloopOn(2)/remoteloopOff(1), and the test stops via sc5520DiagTestReset (or automatically after 10 minutes if sc5520RemLoopTimeout is enabled).
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.498.8.3.7.1.6 snmpwalk -v2c -c public <target> SC5520-MIB::sc5520DiagExtRemoteLoop
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.498.8.3.7.1.6.1 snmpget -v2c -c public <target> SC5520-MIB::sc5520DiagExtRemoteLoop.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.498.8.3.7.1.6.1 i <value>
Start monitoring General DataComm SC5520 DSU/CSU (loopback/DTE-interface configuration) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SC5520-MIB::sc5520DiagExtRemoteLoop OID value, configure state conditions and alerts, and monitor any General DataComm SC5520 DSU/CSU (loopback/DTE-interface configuration) from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.498 | gdc | GDC7616-MIB |
| 1.3.6.1.4.1.498.8 | dsu | DDS-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.498.8.3 | sc5520 | SC5520-MIB |
| 1.3.6.1.4.1.498.8.3.7 | sc5520ExcDiagTable | SC5520-MIB |
| 1.3.6.1.4.1.498.8.3.7.1 | sc5520ExcDiagEntry | SC5520-MIB |
| 1.3.6.1.4.1.498.8.3.7.1.6 | sc5520DiagExtRemoteLoop | SC5520-MIB |