All MIBs › SAF-MPMUX-MIB › switchMode
switchMode
Module: SAF-MPMUX-MIB
OID (symbolic): SAF-MPMUX-MIB::switchMode
OID (numeric): 1.3.6.1.4.1.7571.100.1.1.2.22.5.5
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Integer variable.
What is switchMode?
A read-write selector choosing the terminal's protection-switching topology: unknown(0), freqDiv(1) (frequency diversity, both radios carry the same traffic on different frequencies), hotStandby(2) (one radio active, one standby), or independent(3) (the two radios run unrelated, unprotected links). Admins choose this based on whether the site has spare capacity to dedicate to protection or needs both radios for separate independent links.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.7571.100.1.1.2.22.5.5 snmpwalk -v2c -c public <target> SAF-MPMUX-MIB::switchMode
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.7571.100.1.1.2.22.5.5.1 snmpget -v2c -c public <target> SAF-MPMUX-MIB::switchMode.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.7571.100.1.1.2.22.5.5.1 i <value>
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> switchMode.1
Start monitoring SAF Tehnika microwave radio multiplexer terminal, backhaul indoor unit (IDU) (temperature/frame errors) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SAF-MPMUX-MIB::switchMode OID value, configure state conditions and alerts, and monitor any SAF Tehnika microwave radio multiplexer terminal, backhaul indoor unit (IDU) (temperature/frame errors) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.7571 | saf | SAF-ENTERPRISE |
| 1.3.6.1.4.1.7571.100 | tehnika | SAF-ENTERPRISE |
| 1.3.6.1.4.1.7571.100.1 | microwaveRadio | SAF-ENTERPRISE |
| 1.3.6.1.4.1.7571.100.1.1 | pointToPoint | SAF-ENTERPRISE |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.7571.100.1.1.2 | cfm22 | SAF-MPMUX-MIB |
| 1.3.6.1.4.1.7571.100.1.1.2.22 | mpmux | SAF-MPMUX-MIB |
| 1.3.6.1.4.1.7571.100.1.1.2.22.5 | switchCtrl | SAF-MPMUX-MIB |