SAF-MPMUX-MIB :: rxDelta

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SAF-MPMUX-MIB › rxDelta

rxDelta

Module: SAF-MPMUX-MIB

OID (symbolic): SAF-MPMUX-MIB::rxDelta

OID (numeric): 1.3.6.1.4.1.7571.100.1.1.2.22.5.10

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Integer variable.

What is rxDelta?

A read-write integer setting the minimum receive-level difference (hysteresis) required between the two radios before the protection-switching logic will act on a receive-level-based decision. Prevents the system from flapping back and forth between radios when their signal levels are close and both fluctuating slightly.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.7571.100.1.1.2.22.5.10
snmpwalk -v2c -c public <target> SAF-MPMUX-MIB::rxDelta

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.7571.100.1.1.2.22.5.10.1
snmpget -v2c -c public <target> SAF-MPMUX-MIB::rxDelta.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.7571.100.1.1.2.22.5.10.1 i <value>

Start monitoring SAF Tehnika microwave radio multiplexer terminal, backhaul indoor unit (IDU) (temperature/frame errors) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SAF-MPMUX-MIB::rxDelta OID value, configure state conditions and alerts, and monitor any SAF Tehnika microwave radio multiplexer terminal, backhaul indoor unit (IDU) (temperature/frame errors) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.7571safSAF-ENTERPRISE
1.3.6.1.4.1.7571.100tehnikaSAF-ENTERPRISE
1.3.6.1.4.1.7571.100.1microwaveRadioSAF-ENTERPRISE
1.3.6.1.4.1.7571.100.1.1pointToPointSAF-ENTERPRISE
Numeric OIDNameModule
1.3.6.1.4.1.7571.100.1.1.2cfm22SAF-MPMUX-MIB
1.3.6.1.4.1.7571.100.1.1.2.22mpmuxSAF-MPMUX-MIB
1.3.6.1.4.1.7571.100.1.1.2.22.5switchCtrlSAF-MPMUX-MIB
1.3.6.1.4.1.7571.100.1.1.2.22.5.10rxDeltaSAF-MPMUX-MIB