s5ChasGblConfChngs

Module: S5-CHASSIS-MIB

OID (symbolic): S5-CHASSIS-MIB::s5ChasGblConfChngs

OID (numeric): 1.3.6.1.4.1.45.1.6.3.1.11

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: The total number of configuration changes (other than attachment changes, or physical additions or removals) across all boards in the chassis that have been detected since cold/warm start of the agent.

What is s5ChasGblConfChngs?

A running count of configuration changes (excluding attachment changes and physical add/remove events) across every board in the chassis since the agent last cold/warm started; a useful high-level 'has anything been reconfigured' counter.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.45.1.6.3.1.11
snmpwalk -v2c -c public <target> S5-CHASSIS-MIB::s5ChasGblConfChngs

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.45.1.6.3.1.11.1
snmpget -v2c -c public <target> S5-CHASSIS-MIB::s5ChasGblConfChngs.1

Start monitoring Avaya/Nortel BayStack S5000 series chassis switches (chassis identity/hardware-change counters) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the S5-CHASSIS-MIB::s5ChasGblConfChngs OID value, configure state conditions and alerts, and monitor any Avaya/Nortel BayStack S5000 series chassis switches (chassis identity/hardware-change counters) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.45synopticsCMU-MIB
1.3.6.1.4.1.45.1productsSYNOPTICS-ROOT-MIB
1.3.6.1.4.1.45.1.6series5000SYNOPTICS-ROOT-MIB
1.3.6.1.4.1.45.1.6.3s5ChassisS5-ROOT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.45.1.6.3.1s5ChasGenS5-CHASSIS-MIB
1.3.6.1.4.1.45.1.6.3.1.11s5ChasGblConfChngsS5-CHASSIS-MIB