All MIBs › RackMonitor-MIB › smDeviceHumidityAlarm
smDeviceHumidityAlarm
Module: RackMonitor-MIB
OID (symbolic): RackMonitor-MIB::smDeviceHumidityAlarm
OID (numeric): 1.3.6.1.4.1.534.6.7.1.1.3.2.1.6
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: The device type plugged into RackMonitor.
What is smDeviceHumidityAlarm?
This column reports this sensor's current humidity alarm status, ranging from normal through lowWarning/lowCritical or highWarning/highCritical, mirroring how smDeviceTemperatureAlarm reports temperature status. The source MIB's own DESCRIPTION for this object is copy-pasted from smDeviceStatus and reads 'the device type plugged into RackMonitor,' which does not match either this object's name or its enumerated values; this reading follows the object's real name and enumeration instead.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.534.6.7.1.1.3.2.1.6 snmpwalk -v2c -c public <target> RackMonitor-MIB::smDeviceHumidityAlarm
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.534.6.7.1.1.3.2.1.6.1 snmpget -v2c -c public <target> RackMonitor-MIB::smDeviceHumidityAlarm.1
Start monitoring Eaton/Powerware Rack Monitor environmental monitoring appliances (temperature/humidity/alarm probes) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RackMonitor-MIB::smDeviceHumidityAlarm OID value, configure state conditions and alerts, and monitor any Eaton/Powerware Rack Monitor environmental monitoring appliances (temperature/humidity/alarm probes) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.534 | eaton | EATON-OIDS |
| 1.3.6.1.4.1.534.6 | products | EATON-OIDS |
| 1.3.6.1.4.1.534.6.7 | dataCenter | EATON-OIDS |
| 1.3.6.1.4.1.534.6.7.1 | environmentalMonitor | EATON-OIDS |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.534.6.7.1.1 | insObjects | RackMonitor-MIB |
| 1.3.6.1.4.1.534.6.7.1.1.3 | sensorMonitor | RackMonitor-MIB |
| 1.3.6.1.4.1.534.6.7.1.1.3.2 | smSensorTable | RackMonitor-MIB |
| 1.3.6.1.4.1.534.6.7.1.1.3.2.1 | smSensorEntry | RackMonitor-MIB |
| 1.3.6.1.4.1.534.6.7.1.1.3.2.1.6 | smDeviceHumidityAlarm | RackMonitor-MIB |