RUGGEDCOM-SYS-INFO-MIB :: rcDeviceStsCpuUsage

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › RUGGEDCOM-SYS-INFO-MIB › rcDeviceStsCpuUsage

rcDeviceStsCpuUsage

Module: RUGGEDCOM-SYS-INFO-MIB

OID (symbolic): RUGGEDCOM-SYS-INFO-MIB::rcDeviceStsCpuUsage

OID (numeric): 1.3.6.1.4.1.15004.4.2.2.1

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: The percentage in tenths of percent of available CPU cycles used for device operation as measured over the last second when object was retreived.

What is rcDeviceStsCpuUsage?

Reports CPU utilization, in tenths of a percent, averaged over the last second — for example a value of 455 means 45.5% CPU usage.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.15004.4.2.2.1
snmpwalk -v2c -c public <target> RUGGEDCOM-SYS-INFO-MIB::rcDeviceStsCpuUsage

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.15004.4.2.2.1.1
snmpget -v2c -c public <target> RUGGEDCOM-SYS-INFO-MIB::rcDeviceStsCpuUsage.1

Start monitoring Siemens RuggedCom industrial Ethernet switch (system fault/error/security status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RUGGEDCOM-SYS-INFO-MIB::rcDeviceStsCpuUsage OID value, configure state conditions and alerts, and monitor any Siemens RuggedCom industrial Ethernet switch (system fault/error/security status) from a single console.

How to Use in IPNetwork Monitor

Select a Siemens RuggedCom industrial Ethernet switch (system fault/error/security status) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type rcDeviceStsCpuUsage into the Find box to locate it in the OID tree, then select it and click OK. The percentage in tenths of percent of available CPU cycles used for device operation as measured over the last second when object was retreived. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an Integer32-type OID, Value bounds is the most useful condition here — trigger an alert if utilization exceeds 85%, a common warning threshold before sustained high load affects performance. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.15004ruggedcomRUGGEDCOM-MIB
1.3.6.1.4.1.15004.4ruggedcomMgmtRUGGEDCOM-MIB
Numeric OIDNameModule
1.3.6.1.4.1.15004.4.2rcSysInfoRUGGEDCOM-SYS-INFO-MIB
1.3.6.1.4.1.15004.4.2.2rcDeviceStatusRUGGEDCOM-SYS-INFO-MIB
1.3.6.1.4.1.15004.4.2.2.1rcDeviceStsCpuUsageRUGGEDCOM-SYS-INFO-MIB