RUCKUS-PPPOE-MIB :: ruckusPPPOEConnectionStatus

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › RUCKUS-PPPOE-MIB › ruckusPPPOEConnectionStatus

ruckusPPPOEConnectionStatus

Module: RUCKUS-PPPOE-MIB

OID (symbolic): RUCKUS-PPPOE-MIB::ruckusPPPOEConnectionStatus

OID (numeric): 1.3.6.1.4.1.25053.1.1.8.1.1.1.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Specifies PPPoE connection status. Return up(1) if connection is up, down(2) if connection is down, disabled(3) if PPPoE is disabled.

What is ruckusPPPOEConnectionStatus?

This read-only enumerated value reports the PPPoE connection status: connected, notConnected, or (per the description) disabled if PPPoE isn't enabled. An admin checks it to confirm whether the device's PPPoE WAN link is currently up. For example, a status of notConnected(2) would prompt an admin to check the configured credentials or upstream PPPoE server availability.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.25053.1.1.8.1.1.1.3
snmpwalk -v2c -c public <target> RUCKUS-PPPOE-MIB::ruckusPPPOEConnectionStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.25053.1.1.8.1.1.1.3.1
snmpget -v2c -c public <target> RUCKUS-PPPOE-MIB::ruckusPPPOEConnectionStatus.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> ruckusPPPOEConnectionStatus.1

Start monitoring Ruckus wireless access points/gateways (PPPoE session configuration/connectivity status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RUCKUS-PPPOE-MIB::ruckusPPPOEConnectionStatus OID value, configure state conditions and alerts, and monitor any Ruckus wireless access points/gateways (PPPoE session configuration/connectivity status) from a single console.

How to Use in IPNetwork Monitor

Select a Ruckus wireless access points/gateway (PPPoE session configuration/connectivity status) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type ruckusPPPOEConnectionStatus into the Find box to locate it in the OID tree, then select it and click OK. Specifies PPPoE connection status. Return up(1) if connection is up, down(2) if connection is down, disabled(3) if PPPoE is disabled. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the value is anything other than 'connected', since that indicates the condition this object reports has changed to one worth investigating. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.25053ruckusRootMIBRUCKUS-ROOT-MIB
1.3.6.1.4.1.25053.1ruckusObjectsRUCKUS-ROOT-MIB
1.3.6.1.4.1.25053.1.1ruckusCommonRUCKUS-ROOT-MIB
1.3.6.1.4.1.25053.1.1.8ruckusCommonPPPOEModuleRUCKUS-ROOT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.25053.1.1.8.1ruckusPPPOEMIBRUCKUS-PPPOE-MIB
1.3.6.1.4.1.25053.1.1.8.1.1ruckusPPPOEObjectsRUCKUS-PPPOE-MIB
1.3.6.1.4.1.25053.1.1.8.1.1.1ruckusPPPOEInfoRUCKUS-PPPOE-MIB
1.3.6.1.4.1.25053.1.1.8.1.1.1.3ruckusPPPOEConnectionStatusRUCKUS-PPPOE-MIB