RSERPOOL-MIB :: rserpoolENRPUptime

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsRSERPOOL-MIBrserpoolENRPUptime

rserpoolENRPUptime

Module: RSERPOOL-MIB

OID (symbolic): RSERPOOL-MIB::rserpoolENRPUptime

OID (numeric): 1.3.6.1.3.125.1.1.1.1.5

Node type: OBJECT-TYPE

Type: TimeTicks

Access: read-only

Description: The ENRP service uptime of this ENRP server.

What is rserpoolENRPUptime?

Reports how long, in TimeTicks, this ENRP server's RSerPool registrar service has been running; a recent reset here after an unexpected drop can explain a burst of pool-element re-registrations.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.3.125.1.1.1.1.5
snmpwalk -v2c -c public <target> RSERPOOL-MIB::rserpoolENRPUptime

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.3.125.1.1.1.1.5.1
snmpget -v2c -c public <target> RSERPOOL-MIB::rserpoolENRPUptime.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> rserpoolENRPUptime.1

Start monitoring vendor-neutral, standards-based IETF MIB, RSerPool/ENRP server or pool-element hosts with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RSERPOOL-MIB::rserpoolENRPUptime OID value, configure state conditions and alerts, and monitor any vendor-neutral, standards-based IETF MIB, RSerPool/ENRP server or pool-element hosts from a single console.

How to Use in IPNetwork Monitor

Select a device implementing RSERPOOL-MIB as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type rserpoolENRPUptime into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The ENRP service uptime of this ENRP server. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a TimeTicks-type OID, Value bounds is the most useful condition here — trigger an alert if the value is unexpectedly low (e.g. under 10 minutes), since that indicates a recent, possibly unplanned, reboot or restart. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (5 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.3experimentalAXON-MIB
Numeric OIDNameModule
1.3.6.1.3.125rserpoolMIBRSERPOOL-MIB
1.3.6.1.3.125.1rserpoolMIBObjectsRSERPOOL-MIB
1.3.6.1.3.125.1.1rserpoolENRPServersRSERPOOL-MIB
1.3.6.1.3.125.1.1.1rserpoolENRPTableRSERPOOL-MIB
1.3.6.1.3.125.1.1.1.1rserpoolENRPEntryRSERPOOL-MIB