RR-NORTEL :: nortelIsRunning

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › RR-NORTEL › nortelIsRunning

nortelIsRunning

Module: RR-NORTEL

OID (symbolic): RR-NORTEL::nortelIsRunning

OID (numeric): 1.3.6.1.4.1.562.3.1.1.1.1

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: IsRunning

What is nortelIsRunning?

A read-only integer, per its terse "IsRunning" description, reporting whether the Nortel resiliency service process is currently running on this system. This is a basic process-health indicator an admin checks to confirm the resiliency/shadowing service is actually active before troubleshooting any deeper issue with failover behavior. A value indicating the service isn't running would immediately explain why expected resiliency/shadowing functionality isn't working.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.3.1.1.1.1
snmpwalk -v2c -c public <target> RR-NORTEL::nortelIsRunning

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.3.1.1.1.1.1
snmpget -v2c -c public <target> RR-NORTEL::nortelIsRunning.1

Start monitoring Nortel/Avaya Contact Center server (HA shadowing/switchover resiliency status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RR-NORTEL::nortelIsRunning OID value, configure state conditions and alerts, and monitor any Nortel/Avaya Contact Center server (HA shadowing/switchover resiliency status) from a single console.

How to Use in IPNetwork Monitor

Select a Nortel/Avaya Contact Center server (HA shadowing/switchover resiliency status) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type nortelIsRunning into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports the whether the process is currently running. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an Integer32-type OID, Value bounds is the most useful condition here — trigger an alert if the value drifts significantly from its normal baseline, since an unexpected change often points to a real underlying issue. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelCPM-NORTEL-MIB
1.3.6.1.4.1.562.3meridianNT-Reference-MIB
1.3.6.1.4.1.562.3.1modulesNT-Reference-MIB
Numeric OIDNameModule
1.3.6.1.4.1.562.3.1.1nortelResiliencyRR-NORTEL
1.3.6.1.4.1.562.3.1.1.1nortelResiliencyStatusRR-NORTEL
1.3.6.1.4.1.562.3.1.1.1.1nortelIsRunningRR-NORTEL