RFC1407-MIB :: dsx3TotalCCVs

MIB Reference — IPNetwork Monitor

All MIBsRFC1407-MIBdsx3TotalCCVs

dsx3TotalCCVs

Module: RFC1407-MIB

OID (symbolic): RFC1407-MIB::dsx3TotalCCVs

OID (numeric): 1.3.6.1.2.1.10.30.8.1.9

Node type: OBJECT-TYPE

Type: PerfTotalCount

Access: read-only

Description:

The number of C-bit Coding Violations encountered by a DS3 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0.

What is dsx3TotalCCVs?

This OID holds a count of C-bit coding violations (errors in how data is encoded) that occurred on a DS3 telecommunications line over the past 24 hours. It measures data integrity by counting times the signal wasn't correctly formatted according to the protocol standard. A network operator would check this daily to assess line quality; high numbers indicate a noisy circuit that may need repair.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.2.1.10.30.8.1.9
snmpwalk -v2c -c public <target> RFC1407-MIB::dsx3TotalCCVs

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.2.1.10.30.8.1.9.1
snmpget -v2c -c public <target> RFC1407-MIB::dsx3TotalCCVs.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> dsx3TotalCCVs.1

OID Breakdown

Numeric OIDNameModule
1isoLANART-AGENT
1.3orgBIANCA-BRICK-PPP-MIB
1.3.6dodBIANCA-BRICK-PPP-MIB
1.3.6.1internetBIANCA-BRICK-PPP-MIB
1.3.6.1.2mgmtBKTEL-HFC862-BASE-MIB
1.3.6.1.2.1mib_2CHECKPOINT-MIB-2
1.3.6.1.2.1.10transmissionCHECKPOINT-MIB-2
1.3.6.1.2.1.10.30ds3DS3-MIB
1.3.6.1.2.1.10.30.8dsx3TotalTableDS3-MIB
1.3.6.1.2.1.10.30.8.1dsx3TotalEntryDS3-MIB
1.3.6.1.2.1.10.30.8.1.9dsx3TotalCCVsRFC1407-MIB