RFC1407-EXT-MIB :: cndsx3OperLineType

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › RFC1407-EXT-MIB › cndsx3OperLineType

cndsx3OperLineType

Module: RFC1407-EXT-MIB

OID (symbolic): RFC1407-EXT-MIB::cndsx3OperLineType

OID (numeric): 1.3.6.1.4.1.930.3.6.1.1.1.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: This variable indicates the variety of DS3 C-bit or E3 application implementing this interface. The type of interface affects the interpretation of the usage and error statistics.

The rate of DS3 is 44.736 Mbps and E3 is 34.368 Mbps. The dsx3ClearChannel value means that the C-bits are not used except for sending/receiving AIS.

The values, in sequence, describe:

TITLE: SPECIFICATION: dsx3M23 ANSI T1.107-1988 dsx3SYNTRAN ANSI T1.107-1988 dsx3CbitParity ANSI T1.107a-1989 dsx3ClearChannel ANSI T1.102-1987 e3Framed CCITT G.751 e3Plcp ETSI T/NA(91)18.

What is cndsx3OperLineType?

This read-only enumerated value reports the currently operating DS3 or E3 application type on this interface, such as dsx3M23, dsx3CbitParity, dsx3ClearChannel, e3Framed (CCITT G.751), or e3Plcp (ETSI T/NA(91)18). An admin reads this to confirm which framing standard is actually in effect on the interface, since the interface type affects how usage and error statistics should be interpreted. A value of e3Plcp(8) tells the admin this E3 interface is currently operating using the ETSI PLCP framing standard rather than plain G.751 framing.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.930.3.6.1.1.1.2
snmpwalk -v2c -c public <target> RFC1407-EXT-MIB::cndsx3OperLineType

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.930.3.6.1.1.1.2.1
snmpget -v2c -c public <target> RFC1407-EXT-MIB::cndsx3OperLineType.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> cndsx3OperLineType.1

Start monitoring router/multiplexer DS3/E3 (T3/E3) WAN interface cards (vendor extension of RFC 1407) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RFC1407-EXT-MIB::cndsx3OperLineType OID value, configure state conditions and alerts, and monitor any router/multiplexer DS3/E3 (T3/E3) WAN interface cards (vendor extension of RFC 1407) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.930centillionCENTILLION-ROOT-MIB
1.3.6.1.4.1.930.3extensionsCENTILLION-ROOT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.930.3.6cnds3e3ExtRFC1407-EXT-MIB
1.3.6.1.4.1.930.3.6.1cndsx3OperRFC1407-EXT-MIB
1.3.6.1.4.1.930.3.6.1.1cndsx3OperTableRFC1407-EXT-MIB
1.3.6.1.4.1.930.3.6.1.1.1cndsx3OperEntryRFC1407-EXT-MIB
1.3.6.1.4.1.930.3.6.1.1.1.2cndsx3OperLineTypeRFC1407-EXT-MIB