dsx1ExtCfgT1RxYellowAlarm

Module: RFC1406Ext-MIB

OID (symbolic): RFC1406Ext-MIB::dsx1ExtCfgT1RxYellowAlarm

OID (numeric): 1.3.6.1.4.1.495.2.1.6.53.10.1.58

Node type: OBJECT-TYPE

Type: TimeTicks

Access: read-only

Description: Indicates the total time that a 'yellow alarm' was received on this line interface. A yellow alarm occurs when bit 2 of 256 consecutive channels is set to zero for at least 254 occurrences in D4 format mode or when 16 consecutive patterns of 00FF hex appear in FDL format mode. If no such event has occurred since system startup, then the value will be zero.

What is dsx1ExtCfgT1RxYellowAlarm?

This counter reports the cumulative time this T1 interface has spent receiving a 'yellow alarm,' which the far end signals by zeroing bit 2 of 256 consecutive channels in D4 framing, or by repeating 00FF patterns in FDL framing, to indicate it can't receive a valid signal from this end. Because a yellow alarm reflects a problem the remote end sees on its receive path, admins use it to tell whether a T1 fault lies on the transmit side toward the far end rather than on their own receive path. If dsx1ExtCfgT1RxYellowAlarm starts climbing, an admin would check the outbound transmit signal quality toward the remote T1 equipment rather than assume a local receive fault.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.495.2.1.6.53.10.1.58
snmpwalk -v2c -c public <target> RFC1406Ext-MIB::dsx1ExtCfgT1RxYellowAlarm

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.495.2.1.6.53.10.1.58.1
snmpget -v2c -c public <target> RFC1406Ext-MIB::dsx1ExtCfgT1RxYellowAlarm.1

Start monitoring T1/DS1 CSU/DSU, routers or muxes with T1 interface cards (vendor extension of RFC 1406) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RFC1406Ext-MIB::dsx1ExtCfgT1RxYellowAlarm OID value, configure state conditions and alerts, and monitor any T1/DS1 CSU/DSU, routers or muxes with T1 interface cards (vendor extension of RFC 1406) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.495memotecMEMOTEC-SMI
1.3.6.1.4.1.495.2memotecProductsMEMOTEC-SMI
1.3.6.1.4.1.495.2.1cxProductMEMOTEC-SMI
1.3.6.1.4.1.495.2.1.6cxApplicationCXProduct-SMI
1.3.6.1.4.1.495.2.1.6.53cxDSX1ExtCXProduct-SMI
Numeric OIDNameModule
1.3.6.1.4.1.495.2.1.6.53.10dsx1ExtCfgTableRFC1406Ext-MIB
1.3.6.1.4.1.495.2.1.6.53.10.1dsx1ExtCfgEntryRFC1406Ext-MIB
1.3.6.1.4.1.495.2.1.6.53.10.1.58dsx1ExtCfgT1RxYellowAlarmRFC1406Ext-MIB