All MIBs › RFC1406Ext-MIB › dsx1ExtCfgSctLatchRegTest
dsx1ExtCfgSctLatchRegTest
Module: RFC1406Ext-MIB
OID (symbolic): RFC1406Ext-MIB::dsx1ExtCfgSctLatchRegTest
OID (numeric): 1.3.6.1.4.1.495.2.1.6.53.10.1.61
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Indicates the test results for the T1 transceiver latch register, specifically the second Status Register.
What is dsx1ExtCfgSctLatchRegTest?
This value reports the pass/fail result of a diagnostic test on the T1 transceiver's latch register, specifically its second Status Register. This is a narrower hardware check than the other two register tests, so its failure isolates the fault to the transceiver's status-latching circuitry rather than its signaling or I/O registers. If dsx1ExtCfgSctLatchRegTest reports failed(1) while the other two register tests pass, the admin knows the defect is specific to the status-latch hardware.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.495.2.1.6.53.10.1.61 snmpwalk -v2c -c public <target> RFC1406Ext-MIB::dsx1ExtCfgSctLatchRegTest
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.495.2.1.6.53.10.1.61.1 snmpget -v2c -c public <target> RFC1406Ext-MIB::dsx1ExtCfgSctLatchRegTest.1
Start monitoring T1/DS1 CSU/DSU, routers or muxes with T1 interface cards (vendor extension of RFC 1406) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RFC1406Ext-MIB::dsx1ExtCfgSctLatchRegTest OID value, configure state conditions and alerts, and monitor any T1/DS1 CSU/DSU, routers or muxes with T1 interface cards (vendor extension of RFC 1406) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.495 | memotec | MEMOTEC-SMI |
| 1.3.6.1.4.1.495.2 | memotecProducts | MEMOTEC-SMI |
| 1.3.6.1.4.1.495.2.1 | cxProduct | MEMOTEC-SMI |
| 1.3.6.1.4.1.495.2.1.6 | cxApplication | CXProduct-SMI |
| 1.3.6.1.4.1.495.2.1.6.53 | cxDSX1Ext | CXProduct-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.495.2.1.6.53.10 | dsx1ExtCfgTable | RFC1406Ext-MIB |
| 1.3.6.1.4.1.495.2.1.6.53.10.1 | dsx1ExtCfgEntry | RFC1406Ext-MIB |
| 1.3.6.1.4.1.495.2.1.6.53.10.1.61 | dsx1ExtCfgSctLatchRegTest | RFC1406Ext-MIB |