RFC1406Ext-MIB :: dsx1ExtCfgLossTxClock

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › RFC1406Ext-MIB › dsx1ExtCfgLossTxClock

dsx1ExtCfgLossTxClock

Module: RFC1406Ext-MIB

OID (symbolic): RFC1406Ext-MIB::dsx1ExtCfgLossTxClock

OID (numeric): 1.3.6.1.4.1.495.2.1.6.53.10.1.51

Node type: OBJECT-TYPE

Type: TimeTicks

Access: read-only

Description: Indicates the total time at which the transmit clock was lost on this line interface. If no such event has occurred since system startup, then the value will be zero.

What is dsx1ExtCfgLossTxClock?

This counter reports the cumulative time, in TimeTicks, that this T1/E1 interface has spent with its transmit clock lost since the system last started up. A nonzero and growing value signals a clocking problem on the line, often caused by a faulty cable, card, or upstream timing source, that an admin should investigate before it leads to bit errors. If dsx1ExtCfgLossTxClock reads 0, the port has never lost its transmit clock since boot; a value of 12000 (2 minutes) indicates a brief clock outage occurred.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.495.2.1.6.53.10.1.51
snmpwalk -v2c -c public <target> RFC1406Ext-MIB::dsx1ExtCfgLossTxClock

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.495.2.1.6.53.10.1.51.1
snmpget -v2c -c public <target> RFC1406Ext-MIB::dsx1ExtCfgLossTxClock.1

Start monitoring T1/DS1 CSU/DSU, routers or muxes with T1 interface cards (vendor extension of RFC 1406) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RFC1406Ext-MIB::dsx1ExtCfgLossTxClock OID value, configure state conditions and alerts, and monitor any T1/DS1 CSU/DSU, routers or muxes with T1 interface cards (vendor extension of RFC 1406) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.495memotecMEMOTEC-SMI
1.3.6.1.4.1.495.2memotecProductsMEMOTEC-SMI
1.3.6.1.4.1.495.2.1cxProductMEMOTEC-SMI
1.3.6.1.4.1.495.2.1.6cxApplicationCXProduct-SMI
1.3.6.1.4.1.495.2.1.6.53cxDSX1ExtCXProduct-SMI
Numeric OIDNameModule
1.3.6.1.4.1.495.2.1.6.53.10dsx1ExtCfgTableRFC1406Ext-MIB
1.3.6.1.4.1.495.2.1.6.53.10.1dsx1ExtCfgEntryRFC1406Ext-MIB
1.3.6.1.4.1.495.2.1.6.53.10.1.51dsx1ExtCfgLossTxClockRFC1406Ext-MIB