All MIBs › RFC1406Ext-MIB › dsx1ExtCfgLinkIndex
dsx1ExtCfgLinkIndex
Module: RFC1406Ext-MIB
OID (symbolic): RFC1406Ext-MIB::dsx1ExtCfgLinkIndex
OID (numeric): 1.3.6.1.4.1.495.2.1.6.53.10.1.1
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Identifies the physical port with the T1/E1 (dsx1Ext) interface.
Range of Values: 1 - 2
Default Value: None
Configuration Changed: administrative
What is dsx1ExtCfgLinkIndex?
This integer identifies which of the two physical T1/E1 (dsx1Ext) line interface ports a row in the configuration table applies to. Since the device supports only two T1/E1 ports, this index lets an admin distinguish per-port settings and status, such as alarms or line build-out, when polling or configuring either port individually. For example, a value of 1 selects port 1's row while 2 selects port 2's row, so setting dsx1ExtCfgPortStatus against index 2 configures the second T1/E1 port.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.495.2.1.6.53.10.1.1 snmpwalk -v2c -c public <target> RFC1406Ext-MIB::dsx1ExtCfgLinkIndex
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.495.2.1.6.53.10.1.1.1 snmpget -v2c -c public <target> RFC1406Ext-MIB::dsx1ExtCfgLinkIndex.1
Start monitoring T1/DS1 CSU/DSU, routers or muxes with T1 interface cards (vendor extension of RFC 1406) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RFC1406Ext-MIB::dsx1ExtCfgLinkIndex OID value, configure state conditions and alerts, and monitor any T1/DS1 CSU/DSU, routers or muxes with T1 interface cards (vendor extension of RFC 1406) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.495 | memotec | MEMOTEC-SMI |
| 1.3.6.1.4.1.495.2 | memotecProducts | MEMOTEC-SMI |
| 1.3.6.1.4.1.495.2.1 | cxProduct | MEMOTEC-SMI |
| 1.3.6.1.4.1.495.2.1.6 | cxApplication | CXProduct-SMI |
| 1.3.6.1.4.1.495.2.1.6.53 | cxDSX1Ext | CXProduct-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.495.2.1.6.53.10 | dsx1ExtCfgTable | RFC1406Ext-MIB |
| 1.3.6.1.4.1.495.2.1.6.53.10.1 | dsx1ExtCfgEntry | RFC1406Ext-MIB |
| 1.3.6.1.4.1.495.2.1.6.53.10.1.1 | dsx1ExtCfgLinkIndex | RFC1406Ext-MIB |