RFC1406Ext-MIB :: dsx1ExtCfgLineBuildOut

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › RFC1406Ext-MIB › dsx1ExtCfgLineBuildOut

dsx1ExtCfgLineBuildOut

Module: RFC1406Ext-MIB

OID (symbolic): RFC1406Ext-MIB::dsx1ExtCfgLineBuildOut

OID (numeric): 1.3.6.1.4.1.495.2.1.6.53.10.1.12

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Specifies the attenuation or Line Build Out to be used on the transmitter side of the line.

Options: For T1 1: 0 to 133 feet / 0 dB

2: 133 to 266 feet

3: 266 to 399 feet

4: 399 to 533 feet

5: 533 to 655 feet

6: -7.5 dB

7: -15 dB

8: -22.5 dB

For E1

1: 75 Ohm (coax. cable)

2: 120 Ohm (RJ45 shilded twisted pair)

3: 75 Ohm ( with protection resistor)

4: 120 Ohm ( with protection resistor)

5: 75 Ohm (with high return loss 1:1.15)

6: 120 Ohm (with high return loss 1:1.36)

7: 75 Ohm (with high return loss 1:1.36)

8: N/A

Default Value: 1

Configuration Changed: administrative

What is dsx1ExtCfgLineBuildOut?

This value selects the line build-out setting, meaning transmit attenuation for T1 or termination impedance for E1, to match the cabling in use on this port. Matching this to the actual cable run is necessary to avoid signal reflection or excessive loss, since T1 options are distance-based (feet of cable) while E1 options are impedance-based (coax versus twisted pair). For a T1 run of about 300 feet an admin would set this to 3 (266-399 feet), while an E1 line on 120-Ohm twisted pair would use option 2.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.495.2.1.6.53.10.1.12
snmpwalk -v2c -c public <target> RFC1406Ext-MIB::dsx1ExtCfgLineBuildOut

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.495.2.1.6.53.10.1.12.1
snmpget -v2c -c public <target> RFC1406Ext-MIB::dsx1ExtCfgLineBuildOut.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.495.2.1.6.53.10.1.12.1 i <value>

Start monitoring T1/DS1 CSU/DSU, routers or muxes with T1 interface cards (vendor extension of RFC 1406) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RFC1406Ext-MIB::dsx1ExtCfgLineBuildOut OID value, configure state conditions and alerts, and monitor any T1/DS1 CSU/DSU, routers or muxes with T1 interface cards (vendor extension of RFC 1406) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.495memotecMEMOTEC-SMI
1.3.6.1.4.1.495.2memotecProductsMEMOTEC-SMI
1.3.6.1.4.1.495.2.1cxProductMEMOTEC-SMI
1.3.6.1.4.1.495.2.1.6cxApplicationCXProduct-SMI
1.3.6.1.4.1.495.2.1.6.53cxDSX1ExtCXProduct-SMI
Numeric OIDNameModule
1.3.6.1.4.1.495.2.1.6.53.10dsx1ExtCfgTableRFC1406Ext-MIB
1.3.6.1.4.1.495.2.1.6.53.10.1dsx1ExtCfgEntryRFC1406Ext-MIB
1.3.6.1.4.1.495.2.1.6.53.10.1.12dsx1ExtCfgLineBuildOutRFC1406Ext-MIB