All MIBs › RFC1406Ext-MIB › dsx1ExtCfgIoRegTest
dsx1ExtCfgIoRegTest
Module: RFC1406Ext-MIB
OID (symbolic): RFC1406Ext-MIB::dsx1ExtCfgIoRegTest
OID (numeric): 1.3.6.1.4.1.495.2.1.6.53.10.1.59
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Indicates the test results for the T1/E1 I/O card registers.
What is dsx1ExtCfgIoRegTest?
This value reports the pass/fail result of a diagnostic self-test run against the T1/E1 I/O card's hardware registers. A failed(1) result flags a hardware fault on the I/O card itself, letting an admin distinguish a defective card from a line or configuration problem before dispatching a replacement. If dsx1ExtCfgIoRegTest reads failed(1), the admin should schedule replacement of the T1/E1 I/O card rather than continuing to troubleshoot cabling.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.495.2.1.6.53.10.1.59 snmpwalk -v2c -c public <target> RFC1406Ext-MIB::dsx1ExtCfgIoRegTest
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.495.2.1.6.53.10.1.59.1 snmpget -v2c -c public <target> RFC1406Ext-MIB::dsx1ExtCfgIoRegTest.1
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> dsx1ExtCfgIoRegTest.1
Start monitoring T1/DS1 CSU/DSU, routers or muxes with T1 interface cards (vendor extension of RFC 1406) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RFC1406Ext-MIB::dsx1ExtCfgIoRegTest OID value, configure state conditions and alerts, and monitor any T1/DS1 CSU/DSU, routers or muxes with T1 interface cards (vendor extension of RFC 1406) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.495 | memotec | MEMOTEC-SMI |
| 1.3.6.1.4.1.495.2 | memotecProducts | MEMOTEC-SMI |
| 1.3.6.1.4.1.495.2.1 | cxProduct | MEMOTEC-SMI |
| 1.3.6.1.4.1.495.2.1.6 | cxApplication | CXProduct-SMI |
| 1.3.6.1.4.1.495.2.1.6.53 | cxDSX1Ext | CXProduct-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.495.2.1.6.53.10 | dsx1ExtCfgTable | RFC1406Ext-MIB |
| 1.3.6.1.4.1.495.2.1.6.53.10.1 | dsx1ExtCfgEntry | RFC1406Ext-MIB |
| 1.3.6.1.4.1.495.2.1.6.53.10.1.59 | dsx1ExtCfgIoRegTest | RFC1406Ext-MIB |