RAY3-MIB :: alarmVoltageLow

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsRAY3-MIBalarmVoltageLow

alarmVoltageLow

Module: RAY3-MIB

OID (symbolic): RAY3-MIB::alarmVoltageLow

OID (numeric): 1.3.6.1.4.1.33555.4.1.8.2

Node type: OBJECT-TYPE

Type: AlarmState

Access: read-only

Description: Low voltage alarm state.

What is alarmVoltageLow?

This read-only alarm state reports whether the unit's supply voltage has dropped below its configured minimum threshold, and is the alarm object carried in the tr3VoltageLowAlarm trap alongside voltageUnit. Admins use it to catch a failing or under-sized power supply before it causes a unit to brown out.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.33555.4.1.8.2
snmpwalk -v2c -c public <target> RAY3-MIB::alarmVoltageLow

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.33555.4.1.8.2.1
snmpget -v2c -c public <target> RAY3-MIB::alarmVoltageLow.1

Start monitoring RACOM RAy3 microwave point-to-point/point-to-multipoint radio link unit with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RAY3-MIB::alarmVoltageLow OID value, configure state conditions and alerts, and monitor any RACOM RAy3 microwave point-to-point/point-to-multipoint radio link unit from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.33555racomRAY-MIB
Numeric OIDNameModule
1.3.6.1.4.1.33555.4ray3RAY3-MIB
1.3.6.1.4.1.33555.4.1stationRAY3-MIB
1.3.6.1.4.1.33555.4.1.8alarmRAY3-MIB
1.3.6.1.4.1.33555.4.1.8.2alarmVoltageLowRAY3-MIB