RAISECOM-POWERMONITOR-MIB

MIB Reference — IPNetwork Monitor

All MIBsRAISECOM-POWERMONITOR-MIB

Organization: Raisecom, Inc.

Last Updated: 2011-01-19

Category: Raisecom Networks

Description:

Monitors power supply module status, input voltage, and failure alarms on Raisecom chassis.

Imported Objects

From RAISECOM-BASE-MIB

raisecomAgentOBJECT-IDENTITY

From SNMPv2-SMI

Counter32
Integer32
Unsigned32

What Is RAISECOM-POWERMONITOR-MIB?

RAISECOM-POWERMONITOR-MIB is a vendor-specific MIB from Raisecom Technology that models power-supply monitoring on Raisecom chassis, sitting under the raisecomAgent enterprise subtree. It defines a single raisecomPowerMonitorStateTable (indexed by raisecomPowerIndex) that reports per-power-card serial number, AC/DC power type, voltage reference and measured voltage value, and an overall status (offline, online, power-on), and it pairs this with notification objects — raisecomPowerVoltNormal/Abnormal for voltage transitions, raisecomPowerStatusTrap for status-change alarms, and raisecomDyingGaspTrap for last-gasp power-loss events. This gives operators real-time visibility into power redundancy health on chassis-based access and aggregation equipment without needing physical inspection. It depends on RAISECOM-BASE-MIB for its position in the enterprise tree and typically coexists with Raisecom's environmental and chassis MIBs. It is deployed on Raisecom switches and access devices with pluggable power modules, and administrators can download the RAISECOM-POWERMONITOR-MIB file to load it into their MIB browser.

IPNetwork Monitor allows you to monitor SNMP objects defined in RAISECOM-POWERMONITOR-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

What Can Be Monitored

  • power card serial number and type (AC/DC)
  • voltage reference vs. measured value
  • power module online/offline/power-on status
  • voltage normal/abnormal transition traps
  • dying-gasp (power-loss) notification

Supported Devices

  • Raisecom chassis-based switches and access aggregation devices

Monitoring Examples

An operator polls raisecomPowerMonitorStateTable to check raisecomPowerStatus and raisecomPowerVoltValue for each raisecomPowerIndex power card; a status of offline(1) or a raisecomPowerVoltAbnormal trap combined with a voltage value far from raisecomPowerVoltReference would indicate a failed or failing power supply requiring replacement.

OIDs
OID symbolicOID numericTypeAccessDescription
raisecomPowerMonitor1.3.6.1.4.1.8886.1.24The initial revision of this MIB.
raisecomPowerMonitorNotification1.3.6.1.4.1.8886.1.24.1
NTF raisecomPowerVoltNormal1.3.6.1.4.1.8886.1.24.1.1The trap notification occur when power-card value translating from abnormal to normal.
NTF raisecomPowerVoltAbnormal1.3.6.1.4.1.8886.1.24.1.2The trap notification occur when power-card value translating from normal to abnormal.
NTF raisecomPowerStatusTrap1.3.6.1.4.1.8886.1.24.1.3A raisecomPowerTrap trap is sent when a power alarm generate.
NTF raisecomDyingGaspTrap1.3.6.1.4.1.8886.1.24.1.4Dying gasp.
raisecomPowerMonitorMibObjects1.3.6.1.4.1.8886.1.24.2
raisecomPowerMonitorStateTable1.3.6.1.4.1.8886.1.24.2.1not-accessiblePower monitor state table.
raisecomPowerMonitorStateEntry1.3.6.1.4.1.8886.1.24.2.1.1not-accessiblePower monitor state entry.
U32 raisecomPowerIndex1.3.6.1.4.1.8886.1.24.2.1.1.1Unsigned32not-accessibleSpecify the sequence number of Power.
OCT raisecomPowerSerialNumber1.3.6.1.4.1.8886.1.24.2.1.1.2OCTET STRINGread-onlyspecify the identical serial number of current power card, this string number will be set when device leaving factory
INT raisecomPowerType1.3.6.1.4.1.8886.1.24.2.1.1.3INTEGERread-onlySpecify the current type of the power. ac(1) means the current power AC Input. dc(2) means the current power DC Input.
INT raisecomPowerVoltReference1.3.6.1.4.1.8886.1.24.2.1.1.4INTEGERread-onlySpecify the reference of the volt value of Power.
INT raisecomPowerVoltValue1.3.6.1.4.1.8886.1.24.2.1.1.5INTEGERread-onlySpecify the volt value of Power.
INT raisecomPowerStatus1.3.6.1.4.1.8886.1.24.2.1.1.6INTEGERread-onlyThe status of power alarm.

RFC description

Raisecom power monitoring MIB for tracking power supply voltage, status alarms, and dying gasp notifications.

Start monitoring Raisecom chassis-based switches and access aggregation devices (power-supply monitoring) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download RAISECOM-POWERMONITOR-MIB