RADWIN-MIB-WINLINK1000 :: winlink1000OduAirHssDesiredExtPulseType

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › RADWIN-MIB-WINLINK1000 › winlink1000OduAirHssDesiredExtPulseType

winlink1000OduAirHssDesiredExtPulseType

Module: RADWIN-MIB-WINLINK1000

OID (symbolic): RADWIN-MIB-WINLINK1000::winlink1000OduAirHssDesiredExtPulseType

OID (numeric): 1.3.6.1.4.1.4458.1000.1.5.40.6

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Hub Site Synchronization required external pulse type. Valid values for read write: {typeA(2),typeB(3),typeC(4),typeD(5),typeE(6),typeF(7)}. Valid value for read only: {notApplicable(1)}.

What is winlink1000OduAirHssDesiredExtPulseType?

Sets the desired external synchronization pulse type (A through F) an admin wants this HSS unit to use; valid writable values are the specific types, while 'notApplicable' is the only legal read-only-side value, matching each site's chosen radio frame pattern.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4458.1000.1.5.40.6
snmpwalk -v2c -c public <target> RADWIN-MIB-WINLINK1000::winlink1000OduAirHssDesiredExtPulseType

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.4458.1000.1.5.40.6.1
snmpget -v2c -c public <target> RADWIN-MIB-WINLINK1000::winlink1000OduAirHssDesiredExtPulseType.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.4458.1000.1.5.40.6.1 i <value>

Start monitoring RADWIN point-to-point wireless transmission units with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RADWIN-MIB-WINLINK1000::winlink1000OduAirHssDesiredExtPulseType OID value, configure state conditions and alerts, and monitor any RADWIN point-to-point wireless transmission units from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.4458radwinRADWIN-MIB-WINLINK1000
1.3.6.1.4.1.4458.1000winlink1000RADWIN-MIB-WINLINK1000
1.3.6.1.4.1.4458.1000.1winlink1000OduRADWIN-MIB-WINLINK1000
1.3.6.1.4.1.4458.1000.1.5winlink1000OduAirRADWIN-MIB-WINLINK1000
1.3.6.1.4.1.4458.1000.1.5.40winlink1000OduAirHssRADWIN-MIB-WINLINK1000
1.3.6.1.4.1.4458.1000.1.5.40.6winlink1000OduAirHssDesiredExtPulseTypeRADWIN-MIB-WINLINK1000