RADWIN-MIB-WINLINK1000 :: winlink1000OduAirChainsRxPower

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › RADWIN-MIB-WINLINK1000 › winlink1000OduAirChainsRxPower

winlink1000OduAirChainsRxPower

Module: RADWIN-MIB-WINLINK1000

OID (symbolic): RADWIN-MIB-WINLINK1000::winlink1000OduAirChainsRxPower

OID (numeric): 1.3.6.1.4.1.4458.1000.1.5.9.6

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: read-only

Description: Received Signal Strength of Cpe chains in dBm. Chain 1 RSS: (1 Byte) Chain 2 RSS: (1 Byte) Chain 3 RSS: (1 Byte)

What is winlink1000OduAirChainsRxPower?

Reports the received signal strength, one byte per antenna chain, for up to three MIMO/diversity chains on a multi-chain radio. An admin compares the per-chain values to spot a chain with unusually weak signal, which can point to a faulty connector or misaligned antenna element rather than a whole-link RF problem.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4458.1000.1.5.9.6
snmpwalk -v2c -c public <target> RADWIN-MIB-WINLINK1000::winlink1000OduAirChainsRxPower

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.4458.1000.1.5.9.6.1
snmpget -v2c -c public <target> RADWIN-MIB-WINLINK1000::winlink1000OduAirChainsRxPower.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> winlink1000OduAirChainsRxPower.1

Start monitoring RADWIN point-to-point wireless transmission units with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RADWIN-MIB-WINLINK1000::winlink1000OduAirChainsRxPower OID value, configure state conditions and alerts, and monitor any RADWIN point-to-point wireless transmission units from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.4458radwinRADWIN-MIB-WINLINK1000
1.3.6.1.4.1.4458.1000winlink1000RADWIN-MIB-WINLINK1000
1.3.6.1.4.1.4458.1000.1winlink1000OduRADWIN-MIB-WINLINK1000
1.3.6.1.4.1.4458.1000.1.5winlink1000OduAirRADWIN-MIB-WINLINK1000
1.3.6.1.4.1.4458.1000.1.5.9winlink1000OduAirPerfRADWIN-MIB-WINLINK1000
1.3.6.1.4.1.4458.1000.1.5.9.6winlink1000OduAirChainsRxPowerRADWIN-MIB-WINLINK1000