RADWARE-MIB :: rsSSDvlType

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsRADWARE-MIBrsSSDvlType

rsSSDvlType

Module: RADWARE-MIB

OID (symbolic): RADWARE-MIB::rsSSDvlType

OID (numeric): 1.3.6.1.4.1.89.35.1.63.1.1.1.5

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: regular - ordinary type specBroadcast - for switches that support VLANs as a set of ports and only as a broadcast domain: broadcast frames do not cross VLAN's bounders, but unicast frames may be transmitted between different VLANs. Permits passing of broadcast frames between Vgate's VLANs. specArpReq - for switches that support VLANs as a set of ports and only as a broadcast domain: broadcast frames do not cross VLAN's bounders, but unicast frames may be transmitted between different VLANs. Permits passing of ARP request frames between Vgate's VLANs. specBroadcastAndUnicast - for switches that support VLANs as a set of ports but no frame crosses VLAN's bounders. Permits passing of IP/ARP request broadcast and IP unicast frames between Vgate's VLANs. specArpReqAndUnicast - for switches that support VLANs as a set of ports but no frame crosses VLAN's bounders. Permits passing of ARP request broadcast and IP unicast frames between Vgate's VLANs. This type can be used only for IP VLANs. specSwitch - for switches that support VLANs as a set of ports. This VLAN type is for switching when packets do not have to get to the cpu except when an IP interface defined on the VLAN. In Switch VLAN the cpu don't interfere in the bridging action this is done on the Herzts level (L2).

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.89.35.1.63.1.1.1.5
snmpwalk -v2c -c public <target> RADWARE-MIB::rsSSDvlType

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.89.35.1.63.1.1.1.5.1
snmpget -v2c -c public <target> RADWARE-MIB::rsSSDvlType.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.89.35.1.63.1.1.1.5.1 i <value>

Start monitoring Radware application delivery controller (ADC) appliances, entire product line (base enterprise MIB) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RADWARE-MIB::rsSSDvlType OID value, configure state conditions and alerts, and monitor any Radware application delivery controller (ADC) appliances, entire product line (base enterprise MIB) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.89rndDell-MIB
1.3.6.1.4.1.89.35rndApplicationsDell-MIB
Numeric OIDNameModule
1.3.6.1.4.1.89.35.1rsServerDispatcherRADWARE-MIB
1.3.6.1.4.1.89.35.1.63rsSSDRADWARE-MIB
1.3.6.1.4.1.89.35.1.63.1rsSSDvirtualLanRADWARE-MIB
1.3.6.1.4.1.89.35.1.63.1.1rsSSDvirtualLanTableRADWARE-MIB
1.3.6.1.4.1.89.35.1.63.1.1.1rsSSDvirtualLanEntryRADWARE-MIB
1.3.6.1.4.1.89.35.1.63.1.1.1.5rsSSDvlTypeRADWARE-MIB