RADLAN-IPv6 :: rlInetStaticRouteForwardingStatus

MIB Reference — IPNetwork Monitor · Updated September 21, 2026

All MIBs › RADLAN-IPv6 › rlInetStaticRouteForwardingStatus

rlInetStaticRouteForwardingStatus

Module: RADLAN-IPv6

OID (symbolic): RADLAN-IPv6::rlInetStaticRouteForwardingStatus

OID (numeric): 1.3.6.1.4.1.89.26.28.1.11

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: active - An indication that the route has implication on routing inactive - the route is a backup route or it is down. It is not used in forwarding decision. Down means that the Ip interface on which it is configured is down. (Note: ip interface down may be for two reason - its admin status or the L2 interface , on which the ip interface is configured, status

What is rlInetStaticRouteForwardingStatus?

This read-only object reports whether this static route is active(1), currently used in forwarding decisions, or inactive(2), meaning it's a backup route or down because its associated IP interface (or the underlying L2 interface) is not up. Admins check it to see which of several configured static routes are actually in effect at any given moment, especially when float or backup routes are configured. For example, rlInetStaticRouteForwardingStatus reading inactive(2) on a route tells the admin that route's outgoing interface is currently down, so traffic is not being forwarded via that path.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.89.26.28.1.11
snmpwalk -v2c -c public <target> RADLAN-IPv6::rlInetStaticRouteForwardingStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.89.26.28.1.11.1
snmpget -v2c -c public <target> RADLAN-IPv6::rlInetStaticRouteForwardingStatus.1

Start monitoring Switching equipment built on RADLAN (Marvell) switch reference software (IPv6 addressing/neighbor discovery) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RADLAN-IPv6::rlInetStaticRouteForwardingStatus OID value, configure state conditions and alerts, and monitor any Switching equipment built on RADLAN (Marvell) switch reference software (IPv6 addressing/neighbor discovery) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.89rndDell-MIB
1.3.6.1.4.1.89.26ipSpecDell-IP
1.3.6.1.4.1.89.26.28rlInetStaticRouteTableDell-IPv6
1.3.6.1.4.1.89.26.28.1rlInetStaticRouteEntryDell-IPv6
Numeric OIDNameModule
1.3.6.1.4.1.89.26.28.1.11rlInetStaticRouteForwardingStatusRADLAN-IPv6