RAD-SONET-MIB :: virtualIfIntervalFcsError

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › RAD-SONET-MIB › virtualIfIntervalFcsError

virtualIfIntervalFcsError

Module: RAD-SONET-MIB

OID (symbolic): RAD-SONET-MIB::virtualIfIntervalFcsError

OID (numeric): 1.3.6.1.4.1.164.3.1.6.2.1.6.2.1.10

Node type: OBJECT-TYPE

Type: PerfIntervalCount

Access: read-only

Description: This counter is associated with the number of Frame Check Sequence errors encountered by a Virtual Interface in a particular 15-minute interval in the past 24 hours.

What is virtualIfIntervalFcsError?

The same the number of frames that failed the Frame Check Sequence (FCS) integrity check counter, but for one of the 15-minute intervals in the past 24 hours rather than the live one. Use the historical table to see whether the issue is a persistent VCAT link problem or an isolated event.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.164.3.1.6.2.1.6.2.1.10
snmpwalk -v2c -c public <target> RAD-SONET-MIB::virtualIfIntervalFcsError

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.164.3.1.6.2.1.6.2.1.10.1
snmpget -v2c -c public <target> RAD-SONET-MIB::virtualIfIntervalFcsError.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> virtualIfIntervalFcsError.1

Start monitoring RAD Data Communications SONET/SDH transport device with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RAD-SONET-MIB::virtualIfIntervalFcsError OID value, configure state conditions and alerts, and monitor any RAD Data Communications SONET/SDH transport device from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.164radDACS-MIB
1.3.6.1.4.1.164.3radWanDACS-MIB
1.3.6.1.4.1.164.3.1wanGenDACS-MIB
1.3.6.1.4.1.164.3.1.6diverseIfWanGenDACS-MIB
Numeric OIDNameModule
1.3.6.1.4.1.164.3.1.6.2sonetInterfaceRAD-SONET-MIB
1.3.6.1.4.1.164.3.1.6.2.1prtSonetPerfHistoryRAD-SONET-MIB
1.3.6.1.4.1.164.3.1.6.2.1.6virtualIfStatisticsRAD-SONET-MIB
1.3.6.1.4.1.164.3.1.6.2.1.6.2virtualIfIntervalTableRAD-SONET-MIB
1.3.6.1.4.1.164.3.1.6.2.1.6.2.1virtualIfIntervalEntryRAD-SONET-MIB
1.3.6.1.4.1.164.3.1.6.2.1.6.2.1.10virtualIfIntervalFcsErrorRAD-SONET-MIB