RAD-SONET-MIB :: virtualIfGFPCurrentUpiMismatch

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › RAD-SONET-MIB › virtualIfGFPCurrentUpiMismatch

virtualIfGFPCurrentUpiMismatch

Module: RAD-SONET-MIB

OID (symbolic): RAD-SONET-MIB::virtualIfGFPCurrentUpiMismatch

OID (numeric): 1.3.6.1.4.1.164.3.1.6.2.1.6.7.1.5

Node type: OBJECT-TYPE

Type: PerfCurrentCount

Access: read-only

Description: This counter is associated with the number of received GFP frames that are detected with a mismatch on the UPI field (i.e. value of EXI is not equal to 00000001), encountered by a Virtual Interface in the current 15-minute interval.

What is virtualIfGFPCurrentUpiMismatch?

Counts received GFP frames whose UPI field doesn't equal the expected value (00000001), on this Virtual Interface's Generic Framing Procedure (GFP) encapsulation, during the current 15-minute interval. GFP frame errors like this typically indicate a physical-layer or GFP-mapping problem between this device and its SONET/SDH peer.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.164.3.1.6.2.1.6.7.1.5
snmpwalk -v2c -c public <target> RAD-SONET-MIB::virtualIfGFPCurrentUpiMismatch

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.164.3.1.6.2.1.6.7.1.5.1
snmpget -v2c -c public <target> RAD-SONET-MIB::virtualIfGFPCurrentUpiMismatch.1

Start monitoring RAD Data Communications SONET/SDH transport device with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RAD-SONET-MIB::virtualIfGFPCurrentUpiMismatch OID value, configure state conditions and alerts, and monitor any RAD Data Communications SONET/SDH transport device from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.164radDACS-MIB
1.3.6.1.4.1.164.3radWanDACS-MIB
1.3.6.1.4.1.164.3.1wanGenDACS-MIB
1.3.6.1.4.1.164.3.1.6diverseIfWanGenDACS-MIB
Numeric OIDNameModule
1.3.6.1.4.1.164.3.1.6.2sonetInterfaceRAD-SONET-MIB
1.3.6.1.4.1.164.3.1.6.2.1prtSonetPerfHistoryRAD-SONET-MIB
1.3.6.1.4.1.164.3.1.6.2.1.6virtualIfStatisticsRAD-SONET-MIB
1.3.6.1.4.1.164.3.1.6.2.1.6.7virtualIfGFPCurrentTableRAD-SONET-MIB
1.3.6.1.4.1.164.3.1.6.2.1.6.7.1virtualIfGFPCurrentEntryRAD-SONET-MIB
1.3.6.1.4.1.164.3.1.6.2.1.6.7.1.5virtualIfGFPCurrentUpiMismatchRAD-SONET-MIB