RAD-SONET-MIB :: virtualIfGFPCurrentPtiMismatch

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › RAD-SONET-MIB › virtualIfGFPCurrentPtiMismatch

virtualIfGFPCurrentPtiMismatch

Module: RAD-SONET-MIB

OID (symbolic): RAD-SONET-MIB::virtualIfGFPCurrentPtiMismatch

OID (numeric): 1.3.6.1.4.1.164.3.1.6.2.1.6.7.1.3

Node type: OBJECT-TYPE

Type: PerfCurrentCount

Access: read-only

Description: This counter is associated with the number of rreceived GFP frames that are detected with a mismatch on the PTI field (i.e. value of PTI is not equal to Client Data or Management frame), encountered by a Virtual Interface in the current 15-minute interval.

What is virtualIfGFPCurrentPtiMismatch?

Counts received GFP frames whose PTI field doesn't match Client Data or Management frame values, on this Virtual Interface's Generic Framing Procedure (GFP) encapsulation, during the current 15-minute interval. GFP frame errors like this typically indicate a physical-layer or GFP-mapping problem between this device and its SONET/SDH peer.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.164.3.1.6.2.1.6.7.1.3
snmpwalk -v2c -c public <target> RAD-SONET-MIB::virtualIfGFPCurrentPtiMismatch

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.164.3.1.6.2.1.6.7.1.3.1
snmpget -v2c -c public <target> RAD-SONET-MIB::virtualIfGFPCurrentPtiMismatch.1

Start monitoring RAD Data Communications SONET/SDH transport device with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RAD-SONET-MIB::virtualIfGFPCurrentPtiMismatch OID value, configure state conditions and alerts, and monitor any RAD Data Communications SONET/SDH transport device from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.164radDACS-MIB
1.3.6.1.4.1.164.3radWanDACS-MIB
1.3.6.1.4.1.164.3.1wanGenDACS-MIB
1.3.6.1.4.1.164.3.1.6diverseIfWanGenDACS-MIB
Numeric OIDNameModule
1.3.6.1.4.1.164.3.1.6.2sonetInterfaceRAD-SONET-MIB
1.3.6.1.4.1.164.3.1.6.2.1prtSonetPerfHistoryRAD-SONET-MIB
1.3.6.1.4.1.164.3.1.6.2.1.6virtualIfStatisticsRAD-SONET-MIB
1.3.6.1.4.1.164.3.1.6.2.1.6.7virtualIfGFPCurrentTableRAD-SONET-MIB
1.3.6.1.4.1.164.3.1.6.2.1.6.7.1virtualIfGFPCurrentEntryRAD-SONET-MIB
1.3.6.1.4.1.164.3.1.6.2.1.6.7.1.3virtualIfGFPCurrentPtiMismatchRAD-SONET-MIB