virtualIfGFPCurrentExiMismatch

Module: RAD-SONET-MIB

OID (symbolic): RAD-SONET-MIB::virtualIfGFPCurrentExiMismatch

OID (numeric): 1.3.6.1.4.1.164.3.1.6.2.1.6.7.1.4

Node type: OBJECT-TYPE

Type: PerfCurrentCount

Access: read-only

Description: This counter is associated with the number of received GFP frames that are detected with a mismatch on the EXI field (i.e. value of EXI is not equal to NULL or LINEAR modes), encountered by a Virtual Interface in the current 15-minute interval.

What is virtualIfGFPCurrentExiMismatch?

Counts received GFP frames whose EXI field isn't NULL or LINEAR mode, on this Virtual Interface's Generic Framing Procedure (GFP) encapsulation, during the current 15-minute interval. GFP frame errors like this typically indicate a physical-layer or GFP-mapping problem between this device and its SONET/SDH peer.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.164.3.1.6.2.1.6.7.1.4
snmpwalk -v2c -c public <target> RAD-SONET-MIB::virtualIfGFPCurrentExiMismatch

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.164.3.1.6.2.1.6.7.1.4.1
snmpget -v2c -c public <target> RAD-SONET-MIB::virtualIfGFPCurrentExiMismatch.1

Start monitoring RAD Data Communications SONET/SDH transport device with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RAD-SONET-MIB::virtualIfGFPCurrentExiMismatch OID value, configure state conditions and alerts, and monitor any RAD Data Communications SONET/SDH transport device from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.164radDACS-MIB
1.3.6.1.4.1.164.3radWanDACS-MIB
1.3.6.1.4.1.164.3.1wanGenDACS-MIB
1.3.6.1.4.1.164.3.1.6diverseIfWanGenDACS-MIB
Numeric OIDNameModule
1.3.6.1.4.1.164.3.1.6.2sonetInterfaceRAD-SONET-MIB
1.3.6.1.4.1.164.3.1.6.2.1prtSonetPerfHistoryRAD-SONET-MIB
1.3.6.1.4.1.164.3.1.6.2.1.6virtualIfStatisticsRAD-SONET-MIB
1.3.6.1.4.1.164.3.1.6.2.1.6.7virtualIfGFPCurrentTableRAD-SONET-MIB
1.3.6.1.4.1.164.3.1.6.2.1.6.7.1virtualIfGFPCurrentEntryRAD-SONET-MIB
1.3.6.1.4.1.164.3.1.6.2.1.6.7.1.4virtualIfGFPCurrentExiMismatchRAD-SONET-MIB