RAD-SONET-MIB :: prtSonetVcRxSignalLabel

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › RAD-SONET-MIB › prtSonetVcRxSignalLabel

prtSonetVcRxSignalLabel

Module: RAD-SONET-MIB

OID (symbolic): RAD-SONET-MIB::prtSonetVcRxSignalLabel

OID (numeric): 1.3.6.1.4.1.164.3.1.6.2.4.1.1.2

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: read-only

Description: Signal Label received from network. For VC-3: The SONET standard defines the C2 byte as the path signal label. The purpose of this byte is to communicate the payload type being encapsulated by the SONET Framing OverHead. It allows a single interface to transport multiple payload types simultaneously. For VC-12, VT-1.5: VT path overhead V5 byte allocates bits 5-7 for VT Path Signal Label, to indicate the content of the VT SPE. 000 - Unequipped 001 - Equipped - non specific payload 010 - Asynchronous Mapping 011 - Bit Synchronous Mapping (no longer used) 100 - Byte Synchronous Mapping (TU11 or TU12) 101 - Extended Signal Label for Virtual Concatenation Applications (FCD-155 Default) 110 - Test Signal (0.181) (ITU) 111 - VC AIS (ITU)

What is prtSonetVcRxSignalLabel?

The Signal Label byte actually received from the network for this VC/VT (the C2 byte for VC-3, or V5 bits 5-7 for VC-12/VT-1.5, e.g. 100=byte synchronous mapping, 111=VC AIS). Compare against the locally configured prtSonetVcSignalLabel to detect a payload-type mismatch with the far end.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.164.3.1.6.2.4.1.1.2
snmpwalk -v2c -c public <target> RAD-SONET-MIB::prtSonetVcRxSignalLabel

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.164.3.1.6.2.4.1.1.2.1
snmpget -v2c -c public <target> RAD-SONET-MIB::prtSonetVcRxSignalLabel.1

Start monitoring RAD Data Communications SONET/SDH transport device with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RAD-SONET-MIB::prtSonetVcRxSignalLabel OID value, configure state conditions and alerts, and monitor any RAD Data Communications SONET/SDH transport device from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.164radDACS-MIB
1.3.6.1.4.1.164.3radWanDACS-MIB
1.3.6.1.4.1.164.3.1wanGenDACS-MIB
1.3.6.1.4.1.164.3.1.6diverseIfWanGenDACS-MIB
Numeric OIDNameModule
1.3.6.1.4.1.164.3.1.6.2sonetInterfaceRAD-SONET-MIB
1.3.6.1.4.1.164.3.1.6.2.4prtSonetStatusRAD-SONET-MIB
1.3.6.1.4.1.164.3.1.6.2.4.1prtSonetVcStatTableRAD-SONET-MIB
1.3.6.1.4.1.164.3.1.6.2.4.1.1prtSonetVcStatEntryRAD-SONET-MIB
1.3.6.1.4.1.164.3.1.6.2.4.1.1.2prtSonetVcRxSignalLabelRAD-SONET-MIB