PW-TDM-MIB :: pwTDMCfgClearAlarmThreshold

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsPW-TDM-MIBpwTDMCfgClearAlarmThreshold

pwTDMCfgClearAlarmThreshold

Module: PW-TDM-MIB

OID (symbolic): PW-TDM-MIB::pwTDMCfgClearAlarmThreshold

OID (numeric): 1.3.6.1.2.1.186.1.3.1.16

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-create

Description: Alarm MUST be cleared after the corresponding defect is undetected for the amount of time specified by this object. Object MAY be changed only when the related PW is defined as not active.

What is pwTDMCfgClearAlarmThreshold?

Sets how long, in milliseconds (default 10000), a defect must be absent before a previously-raised alarm is cleared. Paired with pwTDMCfgAlarmThreshold, it implements hysteresis so alarms don't flap on and off during marginal conditions.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.2mgmtAXON-MIB
1.3.6.1.2.1mib_2AXON-MIB
Numeric OIDNameModule
1.3.6.1.2.1.186pwTDMMIBPW-TDM-MIB
1.3.6.1.2.1.186.1pwTDMObjectsPW-TDM-MIB
1.3.6.1.2.1.186.1.3pwTDMCfgTablePW-TDM-MIB
1.3.6.1.2.1.186.1.3.1pwTDMCfgEntryPW-TDM-MIB
1.3.6.1.2.1.186.1.3.1.16pwTDMCfgClearAlarmThresholdPW-TDM-MIB