All MIBs › PT-RADIOLINK-MIB › manualSwitch
manualSwitch
Module: PT-RADIOLINK-MIB
OID (symbolic): PT-RADIOLINK-MIB::manualSwitch
OID (numeric): 1.3.6.1.4.1.193.223.2.7.3.1.20
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Manual switch of protected carrier termination transmitter.
What is manualSwitch?
Manually forces protection switching to a specific carrier termination transmitter (ct11, ct12, ct21, or ct22).
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.193.223.2.7.3.1.20 snmpwalk -v2c -c public <target> PT-RADIOLINK-MIB::manualSwitch
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.193.223.2.7.3.1.20.1 snmpget -v2c -c public <target> PT-RADIOLINK-MIB::manualSwitch.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.193.223.2.7.3.1.20.1 i <value>
Start monitoring Ericsson MINI-LINK microwave radio link equipment (G.826 error-performance) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the PT-RADIOLINK-MIB::manualSwitch OID value, configure state conditions and alerts, and monitor any Ericsson MINI-LINK microwave radio link equipment (G.826 error-performance) from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.193 | ericsson | ANS-COMMON-MIB |
| 1.3.6.1.4.1.193.223 | miniLink | MINI-LINK-MIB |
| 1.3.6.1.4.1.193.223.2 | pt | PT-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.193.223.2.7 | ptRadioLink | PT-RADIOLINK-MIB |
| 1.3.6.1.4.1.193.223.2.7.3 | rltTable | PT-RADIOLINK-MIB |
| 1.3.6.1.4.1.193.223.2.7.3.1 | rltEntry | PT-RADIOLINK-MIB |
| 1.3.6.1.4.1.193.223.2.7.3.1.20 | manualSwitch | PT-RADIOLINK-MIB |