PRVT-RING-EPS-MIB :: prvtRingEpsHoldOffTimer

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsPRVT-RING-EPS-MIBprvtRingEpsHoldOffTimer

prvtRingEpsHoldOffTimer

Module: PRVT-RING-EPS-MIB

OID (symbolic): PRVT-RING-EPS-MIB::prvtRingEpsHoldOffTimer

OID (numeric): 1.3.6.1.4.1.738.1.5.134.1.1.1.1.16

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-create

Description: Range is from 0 to 10 seconds in 100msec intervals

What is prvtRingEpsHoldOffTimer?

This read-create value (0-10000 in 100msec units, i.e. 0-10 seconds, default 0) delays how long a detected link fault must persist before the ring protection switch actually triggers. Admins raise this from 0 to avoid unnecessary ring switchovers from brief, self-clearing link blips.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.738privateVendorOIDPRIV-VENDORDEF-MIB
1.3.6.1.4.1.738.1prvt_productsPRVT-SWITCH-MIB
1.3.6.1.4.1.738.1.5switchPRVT-SWITCH-MIB
Numeric OIDNameModule
1.3.6.1.4.1.738.1.5.134prvtRingEpsMibPRVT-RING-EPS-MIB
1.3.6.1.4.1.738.1.5.134.1prvtRingEpsObjectsPRVT-RING-EPS-MIB
1.3.6.1.4.1.738.1.5.134.1.1prvtRingEpsInstancesPRVT-RING-EPS-MIB
1.3.6.1.4.1.738.1.5.134.1.1.1prvtRingEpsInstanceTablePRVT-RING-EPS-MIB
1.3.6.1.4.1.738.1.5.134.1.1.1.1prvtRingEpsInstanceEntryPRVT-RING-EPS-MIB
1.3.6.1.4.1.738.1.5.134.1.1.1.1.16prvtRingEpsHoldOffTimerPRVT-RING-EPS-MIB