Module: PROMINET-MIB

OID (symbolic): PROMINET-MIB::promPortFlowControlMode

OID (numeric): 1.3.6.1.4.1.2167.3.6.2.1.1.21

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Flow control is used to prevent or reduce the dropping of frames due to the lack of buffer space. Overall, networks are more efficient when a sending station is asked to pause in its sending process, rather than having the transmitted frames dropped.

Flow control is not as efficient when used in conjunction with a shared ports, i.e. when used with a repeater. Therefore, flow control is not recommended for a port connected to shared topologies.

Flow control is most effective when the port is directly connected to an end-station, especially when connected to a server. Flow control is recommended for ports connected directly to end-stations.

When the port is in half-duplex mode, back pressure is used to control the incoming flow. Back pressure essentially forces collisions for short periods of time.

When the port is in full-duplex mode, IEEE 802.3 standard pause frames are used to control the incoming flow.

Note that setting an ether-gigabit(4) port to enable-with-aggressive-backoff(3) results in an error.

The enable-send-only(4) and enable-respond-only(5) are applicable for ether-gigabit and ether-gigabit2 ports only.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2167.3.6.2.1.1.21
snmpwalk -v2c -c public <target> PROMINET-MIB::promPortFlowControlMode

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2167.3.6.2.1.1.21.1
snmpget -v2c -c public <target> PROMINET-MIB::promPortFlowControlMode.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2167.3.6.2.1.1.21.1 i <value>

Start monitoring Prominet Corporation Gigabit Ethernet switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the PROMINET-MIB::promPortFlowControlMode OID value, configure state conditions and alerts, and monitor any Prominet Corporation Gigabit Ethernet switches from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2167prominetPROMINET-MIB
1.3.6.1.4.1.2167.3promChassisPROMINET-MIB
1.3.6.1.4.1.2167.3.6promPortsPROMINET-MIB
1.3.6.1.4.1.2167.3.6.2promPortFlowControlMgtPROMINET-MIB
1.3.6.1.4.1.2167.3.6.2.1promPortFlowControlTablePROMINET-MIB
1.3.6.1.4.1.2167.3.6.2.1.1promPortFlowControlEntryPROMINET-MIB
1.3.6.1.4.1.2167.3.6.2.1.1.21promPortFlowControlModePROMINET-MIB