All MIBs › PROMINET-MIB › promLogTableMaxSize
promLogTableMaxSize
Module: PROMINET-MIB
OID (symbolic): PROMINET-MIB::promLogTableMaxSize
OID (numeric): 1.3.6.1.4.1.2167.10.2.1
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: The maximum number of entries in the log table. Changing this value causes the existing log to be truncated and rebuilt.
What is promLogTableMaxSize?
Writable maximum number of entries in the event log (0-2048); changing it truncates and rebuilds the existing log, so change it deliberately.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2167.10.2.1 snmpwalk -v2c -c public <target> PROMINET-MIB::promLogTableMaxSize
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2167.10.2.1.1 snmpget -v2c -c public <target> PROMINET-MIB::promLogTableMaxSize.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.2167.10.2.1.1 i <value>
Start monitoring Prominet Corporation Gigabit Ethernet switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the PROMINET-MIB::promLogTableMaxSize OID value, configure state conditions and alerts, and monitor any Prominet Corporation Gigabit Ethernet switches from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2167 | prominet | PROMINET-MIB |
| 1.3.6.1.4.1.2167.10 | promEvents | PROMINET-MIB |
| 1.3.6.1.4.1.2167.10.2 | promEventLogMgt | PROMINET-MIB |
| 1.3.6.1.4.1.2167.10.2.1 | promLogTableMaxSize | PROMINET-MIB |