All MIBs › PROBE-MIB › netConfigCellSynchronization
netConfigCellSynchronization
Module: PROBE-MIB
OID (symbolic): PROBE-MIB::netConfigCellSynchronization
OID (numeric): 1.3.6.1.4.1.11.2.4.6.1.1.18
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: ATM network interface addressing mode. Valid values for this field are: HEC - The Header Error Control (DEC) is an 8-bit field and the fifth byte in the header of an ATM cell. The HEC value is calculated from the first four bytes of the cell header. If an error occurs in an ATM cell header, it will be detected in the HEC field. Cells with HEC errors that can not be corrected are discarded by the receiving node. The HEC field can also be used to determine the boundaries of a packet for cell delineation. Valid for ATM OC-3, ATM UTP, ATM T3, ATM E3 with G.832/G.804 framing. PLCP - Physical Layer Convergence Protocol. Each cell is preceded by a 2-byte framing pattern (A1, A2) to enable the receiver to synchronize to the cells. Valid for ATM OC-3, ATM UTP, ATM T3, ATM E3 with G.751 framing.
This field applies only to ATMProbes
What is netConfigCellSynchronization?
Selects how the probe finds ATM cell boundaries on this interface: HEC (Header Error Control, used with G.832/G.804 framing) or PLCP (a 2-byte A1/A2 framing pattern, used with G.751 framing).
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.4.6.1.1.18 snmpwalk -v2c -c public <target> PROBE-MIB::netConfigCellSynchronization
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.4.6.1.1.18.1 snmpget -v2c -c public <target> PROBE-MIB::netConfigCellSynchronization.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.11.2.4.6.1.1.18.1 i <value>
Start monitoring dedicated RMON/network probe appliances, vendor-implemented, may vary by manufacturer with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the PROBE-MIB::netConfigCellSynchronization OID value, configure state conditions and alerts, and monitor any dedicated RMON/network probe appliances, vendor-implemented, may vary by manufacturer from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.11 | hp | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2 | nm | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2.4 | interface | HP-UNIX |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.11.2.4.6 | net | PROBE-MIB |
| 1.3.6.1.4.1.11.2.4.6.1 | netConfigTable | PROBE-MIB |
| 1.3.6.1.4.1.11.2.4.6.1.1 | netConfigEntry | PROBE-MIB |
| 1.3.6.1.4.1.11.2.4.6.1.1.18 | netConfigCellSynchronization | PROBE-MIB |